Abstract: | The physical characteristics and simple lung ventilatory indices (FVC, FEV 1, FEV 1/FVC) of 404 commercial divers employed by companies operating in the North Sea were analysed. These findings were correlated with the diving experience and maximum operating depth of each diver. All the divers were men of average height 176-9 cm, and weight 77-1 kg which is greater than average for active Western males, but only 6% were more than 120% of their predicted weight. The average duration of commercial diving was 7-1 years, 11% of divers having less than one year's experience. Sixty-seven per cent had worked at a maximum depth of 200 ft (61 m) and only 6% had worked deeper than 500 ft (153 m). The mean forced vital capacity (FVC) was 120-4% of the predicted value which indicated that they could voluntarily move large amounts of gas in and out of their lungs. This was greatest in the divers who when deepest. The mean forced expired volume in one second (FEV 1) was 117% of the predicted value showing that expiratory airflow capacity was also increased, but to a lesser extent than the FVC. Thper and activated by zinc. Plasma protein protected the enzyme from both inhibition and activation. ALAD activity was found to be an indicator of the total metal ion concentration in the blood and was therfore considered to be of doubtful value in screening large population for increased lead absorption. |