首页 | 本学科首页   官方微博 | 高级检索  
     

能谱CT最佳单能量肠系膜上动脉成像的价值
引用本文:任占丽,雷雨欣,张敏,陈晓侠,张喜荣,贾永军,于楠,于勇,贺太平. 能谱CT最佳单能量肠系膜上动脉成像的价值[J]. 影像诊断与介入放射学, 2021, 0(1): 15-19
作者姓名:任占丽  雷雨欣  张敏  陈晓侠  张喜荣  贾永军  于楠  于勇  贺太平
作者单位:陕西中医药大学附属医院医学影像科;陕西中医药大学
基金项目:陕西中医药大学学科创新团队建设项目(2019-YS04)。
摘    要:目的 探讨能谱CT最佳单能量技术在肠系膜上动脉成像中降低对比剂用量和提升图像质量的可行性.方法 收集我院肠系膜上动脉CTA受检者40例并随机分为A、B两组,A组采用能谱CT成像模式,对比剂用量450 mg I/kg,扫描后重组最佳单能量、40%ASIR图像;B组行常规120 kVp增强扫描,对比剂用量600 mg I/...

关 键 词:能谱CT  体层摄影术  X线计算机  单能量成像  肠系膜上动脉

Reducing contrast medium dose in superior mesenteric artery imaging with optimal monochromatic energy of dual-energy spectral CT mode
REN Zhan-li,LEI Yu-xin,ZHANG Min,CHEN Xiao-xia,ZHANG Xi-rong,JIA Yong-jun,YU Nan,YU Yong,HE Tai-ping. Reducing contrast medium dose in superior mesenteric artery imaging with optimal monochromatic energy of dual-energy spectral CT mode[J]. Journal of Diagnostic Imaging & Interventional Radiology, 2021, 0(1): 15-19
Authors:REN Zhan-li  LEI Yu-xin  ZHANG Min  CHEN Xiao-xia  ZHANG Xi-rong  JIA Yong-jun  YU Nan  YU Yong  HE Tai-ping
Affiliation:(Department of Medical Imaging,Affiliated Hospital of Shaanxi University of Chinese Medicine,Shaanxi 712000,China)
Abstract:Objective To investigate the possibility of reducing contrast medium(CM)dose and improving image quality in superior mesenteric artery(SMA)imaging with optimal monochromatic energy of dual-energy spectral CT mode.Methods Forty patients undergoing contrast-enhanced abdominal CT were randomly divided into 2 groups.Patients in group A were scanned with spectral CT imaging mode,450 mg I/kg of CM,optimal monochromatic energy,and 40%ASIR reconstruction.Patients in group B underwent conventional CT at 120 kVp with 600 mg I/kg of CM,and 40%ASIR reconstruction.The CT densities and standard deviation(SD)values of SMA and erector muscle at the same level were measured,and the signal to noise ratio(SNR)as well as contrast to noise ratio(CNR)were calculated.The image quality was scored independently by two experienced radiologists using volume rendering,maximum intensity projection,multi-planar reconstruction and curved-planar reconstruction.The CM iodine intake,volume CT dose index(CTDIvol)and dose length product(DLP)were recorded and effective radiation dose(ED)was calculated.The independent sample t test and Mann-Whitney U test were used for statistical analysis.Results The general data,CTDIvol,DLP,ED between the two groups showed no significant difference(P>0.05).The CM iodine intake in group A[(25.47±3.43)g]was significantly(P<0.05)reduced by 26.6%compared with that in group B[(35.80±6.18)g].The CT densities,SNR,and CNR of SMA in group A were significantly higher than those in group B(P<0.05),whereas the SD values in group A were slightly lower than that in group B(P>0.05).The image quality scores of two radiologists showed good consistency(κ>0.80,P<0.05)with significantly(P<0.05)higher scores in group A(4.65±0.59)than that in group B(3.86±0.57).Conclusion At similar radiation dosage,the optimal monochromatic energy of dual-energy spectral CT mode can significantly reduce the CM iodine intake by 26.6%with better image quality than that of conventional 120 kVp enhanced CT of SMA.
Keywords:Spectral CT  Tomography,X-ray computed  Monochromatic energy  Superior mesenteric artery
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号