眼内压测定用于无创颅内压监测的可行性研究
引用本文:艾宏飞,王健,毛思中.眼内压测定用于无创颅内压监测的可行性研究[J].第三军医大学学报,2009,31(2).
作者姓名:艾宏飞  王健  毛思中
作者单位:重庆医科大学附属第二医院神经内科,重庆,400010
摘    要:目的 评估眼内压(intraoeular pressure,IOP)测定用于无创颅内压(intracranial pressure,ICP)监测的可行性.方法 34例(55例次)中枢神经系统疾病患者,通过腰椎穿刺测定ICP,同时采用舣刻度Sehiotz眼压计测量双眼IOP并计算其平均值.结果 ICP与平均IOP之问呈显著正相关(r=0.765,P<0.01).结论 IOP与ICP具有相关性,通过测定IOP可反映ICP.

关 键 词:眼内压  颅内压  可行性

Feasibility of monitoring intracranial pressure by intraocular pressure: report of 55 case times
AI Hong-fei,WANG Jian,MAO Si-zhong.Feasibility of monitoring intracranial pressure by intraocular pressure: report of 55 case times[J].Acta Academiae Medicinae Militaris Tertiae,2009,31(2).
Authors:AI Hong-fei  WANG Jian  MAO Si-zhong
Institution:AI Hong-fei,WANG Jian,MAO Si-zhong(Department of Neurology,Second Affiliated Hospital,Chongqing Medical University,Chongqing 400010,China)
Abstract:Objective To evaluate the feasibility of monitoring intracranial pressure(ICP) by determining intraocular pressure(IOP).Methods ICP(55 case times) in 34 patients with central neural system diseases was measured by lumbar puncture,and their IOP of both eyes was measured by two scales of Schiotz tonometer and the mean value was calculated.Results There was a significant correlation between ICP and mean IOP(P<0.01,r=0.765).Conclusion IOP is correlated well with ICP,thereby reflecting ICP.
Keywords:intraocular pressure  intracranial pressure  feasibility  