首页 | 本学科首页   官方微博 | 高级检索  
     

输卵管超声造影对输卵管通畅性的诊断价值
引用本文:秋阳,勇强,张军,李斌,孔佳,张颖佳. 输卵管超声造影对输卵管通畅性的诊断价值[J]. 临床超声医学杂志, 2012, 14(8): 521-524
作者姓名:秋阳  勇强  张军  李斌  孔佳  张颖佳
作者单位:1. 首都医科大学附属北京安贞医院北京心肺血管疾病研究所超声诊断科,北京市,100029
2. 首都医科大学附属北京安贞医院北京心肺血管疾病研究所妇产科,北京市,100029
摘    要:目的 探讨输卵管超声造影对输卵管通畅性的诊断价值.方法 30例输卵管源性不孕患者,腹腔镜术前全麻条件下行低机械指数SonoVue输卵管超声造影,实时观察造影剂在子宫、输卵管内显影情况,并与腹腔镜检查结果进行对照.结果 输卵管超声造影诊断输卵管狭窄31条,闭塞8条,通畅18条;5条输卵管超声造影考虑通畅,手术中发现输卵管远端积水或粘连闭锁,美蓝通液试验不通;3条输卵管造影考虑远端狭窄或闭塞,腹腔镜下美蓝通液实验通畅.与腹腔镜下美蓝通液检查比较,输卵管超声造影诊断输卵管通畅性的敏感性为87.8%,特异性为78.3%,准确性为86.0%,阳性预测值为92.3%,阴性预测值为72.2%.结论 输卵管造影准确率较高、无创、简便,可免除放射线影响,并可反映输卵管病变原因,具有较高的临床价值.

关 键 词:超声检查  造影剂  低机械指数  输卵管

The clinical application study of hysterosalpingography in tubal origin infertility
QIU Yang , YONG Qiang , ZHANG Jun , Li Bin , KONG Jia , ZHANG Yingjia. The clinical application study of hysterosalpingography in tubal origin infertility[J]. Journal of Ultrasound in Clinical Medicine, 2012, 14(8): 521-524
Authors:QIU Yang    YONG Qiang    ZHANG Jun    Li Bin    KONG Jia    ZHANG Yingjia
Affiliation:Department of Ultrasound, Beijing Anzhen Hospital Affiliated to Capital Medical University, Beijing 100029,China
Abstract:Objective To study the clinical value of contrast-enhanced ultrasound technique in the diagnosis of tubal infertility. Methods Thirty patients were included before laparoscopic surgery. Hysterosalpingography ultrasound imaging was after anesthesia. The real-time ultrasound images of contrast agent in the endometrial cavity and tubal lumen were observed and the results were compare with those from laparoscopy and dyeing examination. Results There was no significaat difference between the imaging results and the laparoscopic methylene blue test with the positive predictive value of 92.3% and the negative predictive value of 72.2%. The sensitivity specifity and accurancy degree of contrast-enhanced ultrasourd exanination in ulterine fallopian tuse were 87.8% ,78.3% ,86.0% ,vespectively. The positive pvedicive and negative preditie value were 92.3% and was 72.2%. Thirty one cases were diagnosed as fallopian tube stenosis by uterine fallopian tube contrast-enhanced ultrasound, 8 obstructed, 18 unobstructed. Remote water or adhesion tubal closure were found during operation in 5 cases which were diagnosed as oviduct tubes by contrast-enhanced ultrasound. But they were found obstructed by methylene blue test. Three cases were cosidered as fallopian tube or obstructed in the remote fallopian tube while methylene blue test in the laparascope showed they were open. Conclusion The technique of contrast -enhanced ultrasound in uterine fallopian tube posseses high clinical value and may reflect the cause of tubal disease with advantages of high accuracy, non-invasiveness, easy operation and non-radioactive effects.
Keywords:Ultrasonography  Contrast agent  Low mechanical index  Fallopian tube
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号