首页 | 本学科首页   官方微博 | 高级检索  
检索        

形变配准算法在肺癌自适应放疗中的应用研究
引用本文:白雪,侯氢,王彬冰,封巍,王升晔.形变配准算法在肺癌自适应放疗中的应用研究[J].中华放射肿瘤学杂志,2018,27(9):825-829.
作者姓名:白雪  侯氢  王彬冰  封巍  王升晔
作者单位:310022 杭州,浙江省肿瘤医院放射物理室(白雪、王彬冰、封巍、王升晔);610005 成都,四川大学原子核科学技术研究所(白雪、侯氢)
基金项目:国家重点研发计划项目部分资助(2016YFC0105103);浙江省医药卫生科技项目部分资助(2017PY013)
摘    要:目的 探讨在肺癌自适应放疗中,图像形变配准方法对患者受量评估的影响。方法 在Raystation治疗计划系统平台上,用两种不同的形变配准算法(混合形变配准和生物动力学形变配准)、不同的形变次序(以放疗前图像作为参考图像和以放疗中期图像作为参考图像),共4种不同的形变配准方法为基础计算累积剂量。选择11例接受自适应放疗的肺癌患者,处方剂量在35.0~61.6 Gy之间,用4种形变配准方法分别计算肺、心脏和GTV的Dmean以及GTV的D98和D2,比较其剂量学差异。结果 用4种不同形变方式计算得到的11例患者肺Dmean的标准差在0.07~0.70 Gy;心脏Dmean的标准差在0.01~0.79 Gy;GTV的Dmean标准差在0.01~2.23 Gy,D98的标准差在0.02~6.51 Gy,D2的标准差在0.01~0.97 Gy。结论 图像形变配准方式的选择对肺癌自适应放疗的累积剂量计算造成了不可忽视的不确定性。

关 键 词:图像形变配准  肺肿瘤  自适应放射疗法  
收稿时间:2017-05-15

Application of deformable image registration in adaptive radiotherapy for lung cancer
Bai Xue,Hou Qing,Wang Binbing,Feng Wei,Wang Shengye.Application of deformable image registration in adaptive radiotherapy for lung cancer[J].Chinese Journal of Radiation Oncology,2018,27(9):825-829.
Authors:Bai Xue  Hou Qing  Wang Binbing  Feng Wei  Wang Shengye
Institution:Department of Radiation Physics,Zhejiang Cancer Hospital,Hangzhou 310022,China (Bai X,Wang BB,Feng W,Wang SY);Institute of Nuclear Science and Technology,Sichuan University,Chengdu 610005,China (Bai X,Hou H)
Abstract:Objective To evaluate the effect of different Methodsof deformable image registration on the dose evaluation in adaptive radiotherapy for lung cancer. Methods By using Raystation Ver4.5 treatment planning system platform,two algorithms (Hybrid-and Biomechanics-based deformable image registration) and two orders (CT images before and during radiotherapy as reference images) were adopted. Four deformable image registration methods were utilized to calculate the accumulative dose. Eleven patients of lung cancer received adaptive radiotherapy for 35.0-61.6 Gy were recruited. The mean doses of lung,heart and GTV and the D98 and D2 of GTV were statistically compared using four methods. Results With the four deformable image registration methods,the standard deviation of the mean lung dose of 11 lung cancer patients was ranged from 0.07 to 0.70 Gy,0.01 to 0.79 Gy for the mean heart dose,0.01 to 2.23 Gy for the mean GTV dose,0.02 to 6.51 Gy for the D98 of GTV and 0.01 to 0.97 Gy for the D2 of GTV,respectively. Conclusion The selection of deformable image registration method causes uncertainty to the calculation of accumulative dose during adaptive radiotherapy for lung cancer.
Keywords:Deformable image registration  Lung neoplasms  adaptive radiotherapy  
点击此处可从《中华放射肿瘤学杂志》浏览原始摘要信息
点击此处可从《中华放射肿瘤学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号