首页 | 本学科首页   官方微博 | 高级检索  
     

三叉神经痛伽玛刀治疗前MRI扫描序列研究
引用本文:李杨,陈兢,王伟,李鹏,戴艳芳,李昌宪,张祝均,徐永华,黄景晞. 三叉神经痛伽玛刀治疗前MRI扫描序列研究[J]. 华西医学, 2010, 0(8): 1495-1498
作者姓名:李杨  陈兢  王伟  李鹏  戴艳芳  李昌宪  张祝均  徐永华  黄景晞
作者单位:[1]四川大学华西医院伽玛刀中心,成都610041 [2]北京宣武医院放射科 ,成都610041 [3]四川大学华西医院放射科,成都610041
摘    要:目的探讨伽玛刀治疗三叉神经痛MRI定位的最佳扫描序列。方法选择2004年7月-2006年3月行伽玛刀手术的原发性三叉神经痛患者60例,随机分为3组,每组各20例。伽玛刀术前上头架定位,然后对3组分别采用快速自旋回波序列(Turbo Spin Echo,TSE)、增强三维小角度激发快速梯度回波序列(enhanced three-dimensiunal fast low angle shot,enhanced3D-FLASH)、三维结构干涉稳态序列(three-dimensional constructive interferencein steady state,3D-CISS)进行扫描,观察三叉神经及周围血管的显示情况。结果①TSE扫描20例三叉神经,14例显示优,血管显示一般。②增强3D-FLASH扫描三叉神经,18例显示优,2例显示良,周围血管显示优。③3D-CISS扫描三叉神经,20例均显示优,周围血管显示良。结论 3D-CISS和增强3D-FLASH序列的融合影像能够清晰地显示三叉神经根及周围血管,有利于伽玛刀的精确定位,具有较高的临床应用价值,可以作为伽玛刀治疗原发性三叉神经痛的常规定位方法。

关 键 词:伽玛刀  三叉神经痛  磁共振成像  放射治疗  定位

Research on the MRI Localization Sequence of Gamma Knife Radiosurgery for Trigeminal Neuralgia
LI Yang,CHEN Jing,WANG Wei,LI Peng,DAI Yan-fang,LI Chang-xian,ZHANG Zhu-jun,XU Yong-hua,HUANG Jing-. Research on the MRI Localization Sequence of Gamma Knife Radiosurgery for Trigeminal Neuralgia[J]. West China Medical Journal, 2010, 0(8): 1495-1498
Authors:LI Yang  CHEN Jing  WANG Wei  LI Peng  DAI Yan-fang  LI Chang-xian  ZHANG Zhu-jun  XU Yong-hua  HUANG Jing-
Affiliation:1. 1. Gamma Knife Center,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,P. R. China; 2. Department of Radiology,Xuanwu Hospital,Beijing 100053,P. R. China; 3. Department of Radiology,West China Hospital,Sichuan University,Chengdu,Sichuan 610041,P. R. China
Abstract:Objective To evaluate the optimal MRI localization sequences of gamma knife radiosurgery for trigeminal neuralgia. Methods From July 2004 to March 2006,sixty patients with primary trigeminal neuralgia were divided into three groups,using MR Turbo Spin Echo ( TSE) ,enhanced three-dimensiunal fast low angle shot 3D-FLASH and three-dimensional constructive interference in steady state ( 3D-CISS) sequence for stereotactic localization,respectively. The trigeminal nerve and surrounding vessels were observed. Results Only 14 trigeminal nerves were precisely displayed by MR TSE sequence,while 20 by 3D-CISS and 18 by 3D-FLASH. The display of surrounding vessels was excellent,good,and general by 3D-FLASH,3D-CISS,and MR TSE,respectively. Conclusion 3D-CISS and enhanced 3D-FLASH fusion image can help achieve accurate orientation of gamma knife,which provides clear images of the trigeminal nerve and the surrounding vessels. Therefore it is of high value in clinical application,which can be used as the conventional localization method for gamma knife radiosurgery in the treatment of primary trigeminal neuralgia.
Keywords:Gamma knife  Trigeminal neuralgia  Magnetic resonance imaging  Radiosurgery  Localization
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号