首页 | 本学科首页   官方微博 | 高级检索  
     


Studies of the solubility of different calcium phosphate ceramic particles in vitro
Authors:C P Klein  J M de Blieck-Hogervorst  J G Wolke  K de Groot
Affiliation:Department of Biomaterials, ACTA Free University, Amsterdam, The Netherlands.
Abstract:In vitro solubility tests of hydroxyapatite, tetracalcium phosphate or tricalcium phosphate particles were performed in lactate, citrate, Gomoris or Michaelis buffer with pH 6.2 or 7.2 and in aqua destillata. The results showed that in general the solubility decreased in the order tetracalcium phosphate greater than tricalcium phosphate greater than hydroxyapatite, except for lactate or citrate buffer where the solubility order was tetracalcium phosphate = tricalcium phosphate greater than hydroxyapatite. The influence of the specific buffer used is much larger than either pH or specific calcium phosphate salt tested. The pH stability of lactate buffer and aqua destillata is very low, the other buffer solvents had a rather stable pH value.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏