Diagnostic performance of combined elastosonography scoring and high-resolution ultrasonography for the differentiation of benign and malignant thyroid nodules |
| |
Authors: | Mohamed Shweel Ehab Mansour |
| |
Affiliation: | 1. Radiology Department, El Minia University Hospital, El Minia, Egypt;2. Radiology Department, Assiut University Hospitals, Assiut, Egypt |
| |
Abstract: | AimTo evaluate the diagnostic performance of the combined use of elstosonography (USE) scoring and high-resolution ultrasonography (HRUS) for the differentiation of benign and malignant thyroid nodule.Patients and methodsForty-seven consecutive patients with 66 thyroid nodules were enrolled in the present study. Thyroid surgery had been already planned for all the patients. All of them were submitted to high-resolution ultrasonography and elastography scoring at the same sitting. The latter was determined with 5-point scoring method. The examination results were compared against pathological findings as the gold standard of reference.ResultsThe sensitivity, specificity, accuracy, positive predictive, and negative predictive values of HRUS in the differential diagnosis of thyroid nodules were 92.0%, 72.9%, 60.1%, 95.0%, and 63.1%, respectively, while that of ultrasound elastography scoring were 75.4%, 85.5%, 86.7%, 71.4%, and 90.5%, respectively. Combined use of both US techniques resulted in a higher diagnostic performance as it showed 95.4%, 94.8%, 95.2%, 82.3% and 98.8% sensitivity, specificity, accuracy, positive predictive, and negative predictive values, respectively.ConclusionsThe use of combined USE and HRS for the differentiation of benign and malignant thyroid nodules resulted in a high diagnostic performance and a significant statistical difference as compared to HRUS or USE alone (P = 0.003). |
| |
Keywords: | US, ultrasound USE, elstosonography HRUS, high-resolution ultrasonography FNA, fine needle aspiration PPV, positive predictive value NPV, negative predictive value |
本文献已被 ScienceDirect 等数据库收录! |
|