首页 | 本学科首页   官方微博 | 高级检索  
     


A new method of phototesting before narrowband UVB therapy
Authors:Wishart J
Affiliation:Department of Dermatology, Greenlane Hospital, Auckland, New Zealand.
Abstract:Narrowband UVB therapy is versatile and generally preferred to broadband sources. Recently, a convenient device has been described which gives 10 different doses simultaneously to the forearm to determine the minimal erythema dose (MED). It is known there is no relation between sun reactive skin type and MED. Twenty-four individuals were tested using 26% increments giving a range of MED of between 0.38 J/cm2 and over 1.5 J/cm2. When compared to conventional window testing in 15 cases, it was found to be identical or within one increment.
Keywords:narrowband (TL-01) UVB therapy    MED (minimal erythema dose)    sun reactive skin type
本文献已被 PubMed 等数据库收录!