首页 | 本学科首页   官方微博 | 高级检索  
检索        


An increased flip angle in late phase Gd-EOB-DTPA MRI shows improved performance in bile duct visualization compared to T2w-MRCP
Authors:Lars Stelter  Patrick Freyhardt  Christian Grieser  Thula Walter  Dominik Geisel  Alexander Baur  Daniel Seehofer  Timm Denecke
Institution:1. Klinik für Radiologie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany;2. Klinik für Allgemein-, Viszeral- und Transplantationschirurgie, Charité – Universitätsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany
Abstract:

Objectives

To estimate the additional value of an increased flip angle of 35° in late phase Gd-EOB-DTPA-enhanced magnetic resonance cholangiography, as compared to T2w-MRCP.

Methods

40 adult patients underwent Gd-EOB-DTPA enhanced MRI of the liver including a T2-weighted 3D TSE MRCP (T2w-MRCP) as well as a late phase T1-weighted THRIVE sequences applying a flip angle of 35° (fa35). Two experienced observers evaluated the images regarding the delineation of the different biliary regions using a three-point grading system. A five-point scale was applied to determine the readers’ confidence in identifying anatomical variations of the biliary tree. ROI analysis was performed to compare the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios.

Results

The quality for visualizing the biliary tree differed between T2w-MRCP and fa35 (p = <0.001). Late phase EOB-MRC was rated as good for delineating the entire biliary system, whereas T2w-MRCP received an overall poor rating. Especially the depiction of the intrahepatic bile ducts was estimated as problematic in T2w-MRCP. T2w-MRCP and fa35 revealed a discordant assessment of anatomical variations in 12.5% of the cases, comprising a generally higher confidence level for fa35 (4.0 ± 1.1 vs. 2.2 ± 1.2, p = <0.001). SNR proofed to be significantly higher in fa35 (p = <0.001), whereas T2w-MRCP revealed a significantly higher CNR (<0.001).

Conclusions

Gd-EOB-DTPA enhanced magnetic resonance cholangiography acquired with a flip angle of 35° revealed a better diagnostic performance compared to T2w-MRCP and might be a valuable adjunct in assessing functional bile duct abnormalities.
Keywords:EOB  Gadoxetic acid  MRI  Bile ducts  Flip angle  T2w-MRCP