首页 | 本学科首页   官方微博 | 高级检索  
     


The relative frequencies of causes of widespread ground-glass opacity: A retrospective cohort
Authors:Michael G. Hewitt  Wallace T. Miller Jr.  Thomas J. Reilly  Scott Simpson
Affiliation:Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, United States
Abstract:

Purpose

The purpose of our study was to determine the relative frequencies of causes of widespread ground-glass opacity (GGO) in an unselected, consecutive patient population and to identify any associated imaging findings that can narrow or reorganize the differential.

Materials and methods

The study was approved by the center's IRB and is HIPPA compliant. Cases with widespread GGO in the radiology report were identified by searching the Radiology Information System. Medical records and CT scan examinations were reviewed for the causes of widespread GGO. Associations between a less dominant imaging finding and a particular diagnosis were analyzed with the chi square test. Our study group consisted of 234 examinations with 124 women and 110 men and a mean age of 53.7 years.

Results

A cause was established in 204 (87.2%) cases. Hydrostatic pulmonary edema was most common with 131 cases (56%). Interstitial lung diseases (ILD) were the next most common, most often hypersensitivity pneumonitis (HP) (n = 12, 5%) and connective tissue disease related ILD (n = 7, 3%). Infection accounted for 5% (12 cases). A few miscellaneous diseases accounted for 5 cases (2.1%). The combination of septal thickening and pleural effusions had a specificity of 0.91 for hydrostatic pulmonary edema (P < .001) while centrilobular nodules and air trapping had a specificity of 1.0 for HP. In 24 (10.2%) patients, increased opacification from expiration was incorrectly interpreted as representing widespread ground glass opacity.The relative frequency of disease dramatically changed according to the setting. In the inpatient setting, diffuse alveolar disease and diffuse infection accounted for all of the known diagnoses. Pulmonary edema accounted for 75% of the diagnoses and diffuse infection accounted for approximately 7%. In the outpatient setting, interstitial lung disease was the most common cause, accounting for 26 of 53 cases (49%).Regarding immunocompromised patients, hydrostatic pulmonary edema was still the most common cause (46%) with diffuse infection (24%) the next most likely diagnosis. For patients with bone marrow suppression, 80% of the cases were due to opportunistic viral infection.

Conclusion

Widespread GGO is most commonly a manifestation of hydrostatic pulmonary edema. Outpatients will most often have HP or connective tissue disease related ILD. Associated findings are helpful for the diagnosis of hydrostatic pulmonary edema and HP.
Keywords:Chest   CT   Ground-glass opacity
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号