首页 | 本学科首页   官方微博 | 高级检索  
     


MR arthrography of the shoulder: Optimizing pulse sequence protocols for the evaluation of cartilage and labrum
Authors:Ali Guermazi  Nabil Jomaah  Daichi Hayashi  Mohamed Jarraya  Jose Roberto Silva Jr.  Jingbo Niu  Emad Almusa  Philippe Landreau  Frank W. Roemer
Affiliation:1. ASPETAR – Qatar Orthopaedic and Sports Medicine Hospital, Sport City Street, Near Khalifa Stadium, P.O. Box 29222, Qatar;2. Department of Radiology, Boston University School of Medicine, 820 Harrison Avenue, FGH Building, 3rd Floor, Boston, MA 02118, United States;3. Department of Radiology, Bridgeport Hospital, Yale University School of Medicine, 267 Grant Street, Bridgeport, CT 06610, United States;4. Clinical Epidemiology Research and Training Unit, Boston University School of Medicine, 650 Albany Street, Suite 200, Boston, MA 02118, United States;5. Department of Radiology, University of Erlangen Nuremberg, Maximiliansplatz 1, D-91054 Erlangen, Germany
Abstract:

Objectives

To compare axial T1weighted fat-saturated (T1w fs) and T1w non-fs sequences, and coronal T1w-fs and T2w-fs sequences, for evaluation of cartilage and labrum using CT arthrography (CTA) as the reference.

Methods

Patients had MR arthrography (MRA) and CTA of the shoulder on the same day. Cartilage was assessed for superficial and full thickness focal and diffuse damage. Labral lesions were graded for Bankart variants and SLAP lesions. CTA images were read for the same features. The diagnostic performance of MRA including area under the curve (AUC) was evaluated against CTA.

Results

When comparing axial sequences, the diagnostic performance for cartilage lesion detection on T1w non-fs was 61.9% (sensitivity) 93.6% (specificity) and 89.5% (accuracy) with AUC 0.782, while that for T1w fs was 61.9%, 94.0%, 89.8% and 0.783. For labral assessment, it was 89.1%, 93.0%, 91.4% and 0.919 for T1w non-fs, and 89.9%, 94.0%, 92.6% and 0.922 for T1w fs. Comparing coronal sequences, diagnostic performance for cartilage was 42.5%, 97.5%, 89.8% and 0.702 for T1w fs, and 38.4%, 98.7%, 90.2%, and 0.686 for T2w fs. For the labrum it was 85.1%, 87.5%, 86.2%, and 0.868 for T1w fs, and 75.7%, 97.5%, 80.8% and 0.816 for T2w fs.

Conclusions

Axial T1w fs and T1w non-fs sequences are comparable in their ability to diagnose cartilage and labral lesions. Coronal T1w fs sequence offers slightly higher sensitivity but slightly lower specificity than T2w fs sequence for diagnosis of cartilage and labral lesions.
Keywords:MR arthrography   CT arthrography   Cartilage   Labrum
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号