首页 | 本学科首页   官方微博 | 高级检索  
检索        


Directivity quantification in hearing aids: fitting and measurement effects
Authors:Ricketts T
Institution:Dan Maddox Hearing Aid Research Laboratory, Vanderbilt Bill Wilkerson Center, Nashville, TN 37212, USA.
Abstract:OBJECTIVE: To evaluate the impact of venting, microphone port orientation, and compression on the electroacoustically measured directivity of directional and omnidirectional behind-the-ear hearing aids. In addition, the average directivity provided across three brands of directional and omnidirectional behind-the-ear hearing aids was compared with that provided by the open ear. DESIGN: Three groups of hearing aids (four instruments in each group) representing three commercial models (a total of 12) were selected for electroacoustic evaluation of directivity. Polar directivity patterns were measured and directivity index was calculated across four different venting configurations, and for five different microphone port angles. All measurements were made for instruments in directional and omnidirectional modes. Single source traditional, and two-source modified front-to-back ratios were also measured with the hearing aids in linear and compression modes. RESULTS: The directivity provided by the open (Knowles Electronics Manikin for Acoustic Research) ear was superior to that of the omnidirectional hearing aids in this study. Although the directivity measured for directional hearing aids was significantly better than that of omnidirectional models, significant variability was measured both within and across the tested models both on average and at specific test frequencies. Both venting and microphone port orientation affected the measured directivity. Although compression reduced the magnitude of traditionally measured front-to-back ratios, no difference from linear amplification was noted using a modified methodology. CONCLUSIONS: The variation in the measured directivity both within and across the directional microphone hearing aid brands suggests that manufacturer's specification of directivity may not provide an accurate index of the actual performance of all individual instruments. The significant impact of venting and microphone port orientation on directivity indicate that these variables must be addressed when fitting directional hearing aids on hearing-impaired listeners. Modified front-to-back ratio results suggest that compression does not affect the directivity of hearing aids, if it is assumed that the signal of interest from one azimuth, and the competing signal from a different azimuth, occur at the same time.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号