首页 | 本学科首页   官方微博 | 高级检索  
     


Can the size principle be detected in conventional emg recordings?
Authors:Mustafa Ertas,Erik St  lberg,Bj  rn Falck
Affiliation:Mustafa Ertas,Erik Stålberg,Björn Falck
Abstract:According to Henneman's size principle, small motor units are recruited before large ones. It is commonly believed that this can be detected in routine conventional EMG recordings even among the earliest recruited motor units. That is, the MUP amplitude, area, and thickness should increase with recruitment order. We studied the first four motor unit potentials (MUPs) recruited within the pickup area of the electrodes. Data were obtained from 179 different sites in monopolar recordings and in 153 concentric recordings from 5 health subjects. In the pooled material, amplitude, area, and thickness increased slightly between consecutively recruited MUPs. However, at individual recording sites the size of consecutively recruited MUPs varied considerably. At some recording sites the first recruited MUP had the largest amplitude and the later MUPs has successively smaller amplitudes. We conclude that, at individual recording sites, the size principle cannot be detected in low threshold motor units with monopolar or concentric EMG electrodes. The reason for this is the small uptake area of these electrodes in relation to the motor unit territory. © 1995 John Wiley & Sons, Inc.
Keywords:size principle  quantitative EMG analysis  recruitment  threshold  motor unit