首页 | 本学科首页   官方微博 | 高级检索  
     


Fast lung nodule detection in chest CT images using cylindrical nodule-enhancement filter
Authors:Atsushi Teramoto  Hiroshi Fujita
Affiliation:1. Faculty of Radiological Technology, School of Health Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake-city, Aichi, 470-1192, Japan
2. Department of Intelligent Image Information, Graduate School of Medicine Gifu University, 1-1 Yanagido, Gifu-city, Gifu, 501-1194, Japan
Abstract:

Purpose

Existing computer-aided detection schemes for lung nodule detection require a large number of calculations and tens of minutes per case; there is a large gap between image acquisition time and nodule detection time. In this study, we propose a fast detection scheme of lung nodule in chest CT images using cylindrical nodule-enhancement filter with the aim of improving the workflow for diagnosis in CT examinations.

Methods

Proposed detection scheme involves segmentation of the lung region, preprocessing, nodule enhancement, further segmentation, and false-positive (FP) reduction. As a nodule enhancement, our method employs a cylindrical shape filter to reduce the number of calculations. False positives (FPs) in nodule candidates are reduced using support vector machine and seven types of characteristic parameters.

Results

The detection performance and speed were evaluated experimentally using Lung Image Database Consortium publicly available image database. A 5-fold cross-validation result demonstrates that our method correctly detects 80 % of nodules with 4.2 FPs per case, and detection speed of proposed method is also 4–36 times faster than existing methods.

Conclusion

Detection performance and speed indicate that our method may be useful for fast detection of lung nodules in CT images.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号