PaCO(2)/ETCO(2) gradient: early indicator of thrombolysis efficacy in a massive pulmonary embolism |
| |
Authors: | Thys F Elamly A Marion E Roeseler J Janssens P El Gariani A Meert P Verschuren F Reynaert M |
| |
Affiliation: | Service des Urgences, Cliniques Universitaires Saint-Luc, Université de Louvain, Avenue Hippocrate 10, 1200 Brussels, Belgium. |
| |
Abstract: | End tidal CO(2) measurement may be helpful in detecting the efficacy of thrombolysis after a massive pulmonary embolism. We report the case of a 76-year-old man with a massive pulmonary embolism, who required early intubation and mechanical ventilation. Thrombolysis with rtpA (total dosage: 60 mg) was initiated. During this procedure, clinical data, arterial blood gases and end-tidal CO(2) with a capnograph were recorded. Before thrombolysis the P(a-ET)CO(2) gradient was raised to 25 mmHg. During thrombolysis, the clinical data improved and the P(a-ET) gradient fell to 14 mmHg. We postulate that the P(a-ET)CO(2) gradient seems to be a reasonable indicator of efficacy of thrombolysis in this setting. However, the gradient did not return to normal values (4-5 mmHg). The possible reasons for this may be that during mechanical ventilation there was a large ventilation-perfusion ratio and the cardiac output may have still reduced. With these limitations, we conclude that the P(a-ET)CO(2) gradient should be evaluated as an indicator of pulmonary reperfusion in massive pulmonary embolism. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|