首页 | 本学科首页   官方微博 | 高级检索  
检索        

GC法测定肛安栓中冰片的含量
引用本文:高辉,徐丽华.GC法测定肛安栓中冰片的含量[J].齐鲁药事,2012,31(3):145-146.
作者姓名:高辉  徐丽华
作者单位:山东省食品药品检验所,山东,济南,250101
摘    要:目的采用气相色谱法测定肛安栓中冰片的含量。方法 Agilent HP-FFAP石英毛细管柱(0.25 mm×30.0m,0.25μm),柱温130℃,进样口温度180℃;检测器温度230℃;氢离子火焰检测器;恒流;分流比40∶1。结果冰片的进样量在0.058~1.450 0μg之间与峰面积呈良好的线性关系,相关系数r=0.999 97,平均加样回收率为98.30%,RSD=1.70%(n=6)。结论本法简便、准确,可用于肛安栓中冰片的含量测定。

关 键 词:肛安栓  冰片  气相色谱法  含量测定

Determination of borneol in Gangan Suppositories by GC
GAO Hui , XU Li-hua.Determination of borneol in Gangan Suppositories by GC[J].qilu pharmaceutical affairs,2012,31(3):145-146.
Authors:GAO Hui  XU Li-hua
Institution:( Shandong Institute for Food and Drug Control,Jinan 250101, China)
Abstract:Objective To establish a GC method for the determination of borneol in Gangan Suppositories. Methods Agi- lent HP - FFAP capillary column ( 0.25 mm×30.0 m,0.25 um ) was adopted with a flame ionization detector. The column tem- perature was 130 ℃ ,the inlet temperature was 180 ℃ and the deteetor temperature was 230 ℃. The constant flow mode was conducted with the split ratio of 40: 1. Results The linear range of borneol was 0. 058 - 1. 450 0 ug ( r = 0. 999 97 ). The average recovery was 98.30% and the RSD was 1.70% ( n = 6). Conclusion The method was simple and accurate, and it can be used for the determination of borneol in Gangan Suppositories.
Keywords:Gangan Suppositories  Borneol  GC  Determination
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号