首页 | 本学科首页   官方微博 | 高级检索  
     


Whole-body MRI including diffusion-weighted imaging (DWI) for patients with recurring prostate cancer: technical feasibility and assessment of lesion conspicuity in DWI
Authors:Eiber Matthias  Holzapfel Konstantin  Ganter Carl  Epple Kathrin  Metz Stephan  Geinitz Hans  Kübler Hubert  Gaa Jochen  Rummeny Ernst J  Beer Ambros J
Affiliation:1. Department of Radiology, Technische Universit?t München, Munich, Germany;2. Department of Radiotherapy and Radiooncology, Technische Universit?t München, Munich, Germany;3. Department of Urology, Technische Universit?t München, Munich, Germany;4. Department of Nuclear Medicine, Technische Universit?t München, Munich, Germany
Abstract:

Purpose:

To evaluate the principal methodological aspects of whole‐body magnetic resonance imaging (MRI) including diffusion‐weighted imaging (DWI) with background suppression using a time‐optimized protocol for restaging of prostate cancer patients in a technical feasibility study.

Materials and Methods:

Seventeen patients underwent MRI at 1.5T from the base of the skull to the proximal thigh using axial T1‐weighted (T1w), T2w short‐tau inversion recovery (STIR), and DWI (b‐values: 50 and 500 s/mm2) and sagittal T1w and T2w STIR of the spine. Apparent diffusion coefficient (ADC) values of liver, spleen, kidney, muscle, and bone were measured. Image quality in DWI was assessed by using a scale from 0–9. Contrast‐to‐noise ratios (CNRs) of lymph node and bone metastases were determined in T1w, T2w STIR, and DWI. Bone metastases were further subclassified according to their Hounsfield units (HU) in computed tomography (CT).

Results:

Mean acquisition and mean room times were 66:20 and 75:21 minutes, respectively. ADC values of normal organs showed good concordance with reported data. Good to excellent image quality was observed for DWI (mean scores 7.41–8.00) with the exception of the neck (mean score 4.76). CNR of DWI (b‐value 50 s/mm2) for lymph node metastases was clearly superior compared to all other sequences. For bone metastases T1w performed significantly better for sclerotic lesions (HU > 600), DWI (b‐value 50 s/mm2) for nonsclerotic lesion (HU < 300).

Conclusion:

In patients with recurrent prostate cancer a whole‐body MR protocol including DWI is technically robust. Due to the high CNR of DWI compared to T1w and T2w STIR, detection of malignant lesions should be facilitated by DWI, except for sclerotic bone metastases. J. Magn. Reson. Imaging 2011;33:1160–1170. © 2011 Wiley‐Liss, Inc.
Keywords:whole body DWI  prostate cancer  technical feasibility  image quality  lesion conspicuity
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号