Fast Monte Carlo simulation of DNA damage induction by Auger-electron emission
Abstract:Abstract

Purpose: A local damage model (LDM) was developed to estimate the biological efficiency of Auger-electron-emitting radionuclides.

Materials and methods: The LDM required information on the local dose distribution, local energy spectrum, and clustered DNA damage yields in the cell nucleus. To apply the model, the nucleus was divided into concentric shells where each shell contributed its own local dose, energy spectrum, and damage yield. The local doses and energy spectra were computed using the PENELOPE (PENetration and Energy LOss of Positrons and Electrons) code. The DNA damage yields were estimated using the MCDS (Monte Carlo damage simulation) code.

Results: For a typical 4-μm radius mammalian cell nucleus, the absorbed doses to the cell nucleus per unit cumulated activity, equal to 0.0065, 0.00418, 0.0028, 0.0027 and 0.0015 Gy Bq?1 s?1 for 125I, 119Sb, 123I, 111In and 99mTc, were within 6% difference with the MIRD (Medical Internal Radiation Dose) published data. The simulated total (simple and complex) single-strand break (SSB) and double-strand break (DSB) yields were in the same order, i.e., 125I > 119Sb > 123I > 111In > 99mTc. The agreement between present results and literature data for the DNA damage yields was generally good. More than 75% of the total SSB and DSB yields were contributed from regions within 2.5 μm of the nucleus center.

Conclusions: The proposed methodology was computationally efficient and could be applied to other irradiation geometries such as cell clusters.
Keywords:Auger electron  DNA damage  local damage model  PENELOPE  MCDS
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号