A new way to use transit-time flow measurement for coronary artery bypass grafting
Authors:Lukas Stastny  Markus Kofler  Vitalijs Zujs  Elfriede Ruttmann  Julia Dumfarth  Juliane Kilo  Alexandra Brix  Simone Gasser  Adel Sakic  Thomas Schachner  Michael Grimm  Nikolaos Bonaros
Institution:Department of Cardiac Surgery, Medical University of Innsbruck, Innsbruck, Austria
Abstract:Open in a separate windowOBJECTIVESTransit-time flow measurement is a recognized method for graft evaluation in coronary surgery. However, single flow measurement has been associated with a low specificity for detecting graft dysfunction. The goal of this study was to assess the value of transit-time flow measurement for assessing in situ internal mammary artery grafts during non-existent native coronary circulation and the relevance of collateral blood flow in target vessels.METHODSBetween 2014 and 2018, a total of 134 patients undergoing on-pump coronary artery bypass grafting were evaluated using transit-time flow measurement. We analysed 111 single left internal mammary artery and 57 single right internal mammary artery bypasses. Correlations between coronary relevant parameters were calculated using Spearman’s ρ coefficient. Risk factors for decreased flow with an arrested heart (FAH) <30 ml/min and an increased pulsatility index (PI) >3.0 as well as flow reduction >30% were calculated.RESULTSFAH correlated with the diameter of the target vessel (Spearman’s ρ = 0.32; P < 0.001), the amount of blood distribution (Spearman’s ρ = 0.34; P < 0.001), the PI (Spearman’s ρ = 0.19; P = 0.019) and the degree of stenosis (Spearman’s ρ = −0.17; P = 0.042). The percentage of flow change was found to correlate with the PI (Spearman’s ρ = −0.47; P < 0.0001), the degree of stenosis (Spearman’s ρ = 0.42; P < 0.001), the diameter of the target vessel (Spearman’s ρ = −0.22; P = 0.008) and the area of blood distribution (Spearman’s ρ = −0.19; P = 0.018). A small blood distribution area was the only risk factor for decreased FAH odds ratio (OR) 8.43, confidence interval (CI) 95% (3.04–23.41); P < 0.001]. Binary logistic regression identified PI OR 2.05, CI 95% (1.36–3.10); P = 0.001], FAH OR 0.98, CI 95% (0.97–0.99); P = 0.005] and degree of stenosis OR 0.95, CI 95% (0.92–0.99); P = 0.011] as risk factors for decreased flow after cardiopulmonary bypass (<30 ml/min). An increased PI (>3) was mainly influenced by percentage of flow change OR 0.99, CI 95% (0.98–1.00); P = 0.031].CONCLUSIONSFAH and percentage of flow change are related to the dimensions of the target vessel and the degree of stenosis. The addition of flow measurements with the heart arrested provides additional information about the bypass graft, the quality of the anastomosis and the physiology of the coronary circulation.
Keywords:Transit-time flow measurement  Coronary artery bypass grafting  Quality control
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号