首页 | 本学科首页   官方微博 | 高级检索  
检索        


Safety,efficacy, and cost of intraoperative indocyanine green angiography compared to intraoperative catheter angiography in cerebral aneurysm surgery
Institution:Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, 350 W. Thomas Road, Phoenix, AZ 85013, USA
Abstract:Intraoperative angiography in cerebrovascular neurosurgery can drive the repositioning or addition of aneurysm clips. Our institution has switched from a strategy of intraoperative digital subtraction angiography (DSA) universally, to a strategy of indocyanine green (ICG) videoangiography with DSA on an as-needed basis. We retrospectively evaluated whether the rates of perioperative stroke, unexpected postoperative aneurysm residual, or parent vessel stenosis differed in 100 patients from each era (2002, “DSA era”; 2007, “ICG era”). The clip repositioning rate for neck residual or parent vessel stenosis did not differ significantly between the two eras. There were no differences in the rate of perioperative stroke or rate of false-negative studies. The per-patient cost of intraoperative imaging within the DSA era was significantly higher than in the ICG era. The replacement of routine intraoperative DSA with ICG videoangiography and selective intraoperative DSA in cerebrovascular aneurysm surgery is safe and effective.
Keywords:Cerebrovascular surgery  Indocyanine green  Intraoperative angiography
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号