首页 | 本学科首页   官方微博 | 高级检索  
检索        

第三磨牙倾斜不同角度对下颌双端固定桥应力的影响
引用本文:张翼,吴娴,张一岭,陈艳,刘波,廖沐莹.第三磨牙倾斜不同角度对下颌双端固定桥应力的影响[J].口腔颌面修复学杂志,2011,12(3):134-138.
作者姓名:张翼  吴娴  张一岭  陈艳  刘波  廖沐莹
作者单位:1. 解放军第一七四医院口腔科,福建,361003
2. 福建医科大学口腔医学院,福建,361003
3. 厦门大学土木工程系,福建,361005
4. 解放军第一七四医院,福建,361003
摘    要:目的:下颌第一二磨牙缺失三基牙双端固定桥修复的条件下,分析近中倾斜不同角度的第三磨牙作为基牙后受力时修复体、牙体组织及牙周膜的应力分布情况,为临床修复提供理论依据.方法:在已建好的第一二磨牙缺失三基牙双端固定桥修复的三维有限元模型基础上,将第三磨牙近中倾斜0°、10°、20°、30°和40°,通过Ansys软件分析修复...

关 键 词:固定桥  倾斜基牙  有限元分析  应力分析

Effect of different tilting angels of third molar on the stress distribution of the rigid fixed bridge in deletion of first molar and second molar in mandibular
ZHANG Yi,WU Xian,ZHANG Yi-ling,CHEN Yan,LIU Bo,LIAO Mu-ying.Effect of different tilting angels of third molar on the stress distribution of the rigid fixed bridge in deletion of first molar and second molar in mandibular[J].Chinese Journal of Prosthodontics,2011,12(3):134-138.
Authors:ZHANG Yi  WU Xian  ZHANG Yi-ling  CHEN Yan  LIU Bo  LIAO Mu-ying
Institution:ZHANG Yi,WU Xian,ZHANG Yi-ling,CHEN Yan,LIU Bo,LIAO Mu-ying.(Department of stomatology,The 174th Hospital of PLA,Fujian 361003,China)
Abstract:Objective: To evaluate the influence of different tilting angles of the mandibular third molar on the stress distribution in the restoration,odontal tissue and periodontal membrane as bridge abutments after the restoration of fixed partial denture.Methods: Based on a 3-D finite element model of three abutments of the rigid fixed bridge in deletion of first molar and second molar in mandibular,evaluate the influence of the mandibular third molar with different tilting angles of 0°,10°,20°,30°and 40°on the stress distribution in the restoration,odontal tissue and periodontal membrane by a software named Ansys.Results: When the tilting angle of third molar was increasing,the max Von Mises stresses of the restoration,odontal tissue and periodontal membrane were increasing.When third molar tilted at 30°,the Von Mises stress peak value(9.11MPa) on the peridental membrane of third molar was 2.4 times than the normal third molar(3.81MPa).Conclusions: The tooth tilted more than 30°could not be selected as an abutment in the restoration of fixed partial denture,and the clinicians should lower the height of the cusp to reduce the oblique load of the abutment when fixed bridge was used as a treatment.
Keywords:rigid fixed bridge  tilted abutment  finite element analysis  stress analysis  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号