首页 | 本学科首页   官方微博 | 高级检索  
     


Whole body plethysmography reveals differential ventilatory responses to ozone in rat models of cardiovascular disease
Authors:Janice A. Dye  Allen D. Ledbetter  Mette C. Schladweiler  Daniel L. Costa
Affiliation:1. Environmental Public Health Division, NHEERL, U.S. Environmental Protection Agency, Research Triangle Park, NC, USA and;2. National Program for Air Climate &3. Energy Research, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, USA
Abstract:Abstract

To elucidate key factors of host susceptibility to air pollution, healthy and cardiovascular (CV)-compromised rats were exposed to air or ozone (O3) at 0.25, 0.5, or 1.0?ppm for 4?h. We hypothesized that rat strains with the least cardiac reserve would be most prone to develop significant health effects. Using flow whole body plethysmography (FWBP), ventilatory responses in healthy 3-month-old male rats [i.e. Wistar–Kyoto (WKY), Wistar (WIS), and Sprague–Dawley (SD) strains] were compared with hypertensive [i.e. spontaneously hypertensive (SH), fawn-hooded-hypertensive (FHH), and SH-stroke-prone (SHSP)] strains and obese [i.e. SH-heart failure-prone (SHHF) and JCR:LA-cp, atherosclerosis-prone (JCR)] strains. SH were slower to acclimate to the FWBP chambers. At 0-h post-air-exposure, SHSP and SHHF exhibited hyperpnea, indicative of cardiopulmonary insufficiency. At 0-h-post-O3, all but one strain showed significant concentration-dependent decreases in minute volume [MV?=?tidal volume (TV)?×?breathing frequency]. Comparing air with 1.0?ppm responses, MV declined 20–27% in healthy, 21–42% in hypertensive, and 33% in JCR rats, but was unchanged in SHHF rats. Penh increased significantly in all strains, with disproportionate increases in “responder” WKY and FHH strains. By 20?h, most changes had resolved, although Penh remained elevated in WKY, SH, and SHSP. Based on the effective dose estimates (O3?ppm?×?h?×?MV), the most CV-compromised (SHSP and SHHF) strains received significantly greater O3 lung deposition (25% and 40%, respectively). Data support epidemiologic associations that individuals with cardiopulmonary insufficiency are at greater risk for urban pollutant exposure due, in part, to enhanced lung deposition and exacerbation of hypoxia and pathophysiologic processes of heart failure.
Keywords:Cardiovascular disease models  ozone  rat  ventilatory parameters  whole body plethysmography
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号