高频超声造影对胆囊内蛔虫残骸的诊断价值
引用本文:徐本华,董怡,张琪,杨道辉,邱艺杰,王文平.高频超声造影对胆囊内蛔虫残骸的诊断价值[J].中国临床医学,2020,27(6):1017-1019.
作者姓名:徐本华  董怡  张琪  杨道辉  邱艺杰  王文平
作者单位:复旦大学附属中山医院超声科, 上海 200032
基金项目:国家自然科学基金(81501471),上海市科学与技术委员会"科技创新行动计划"临床医学领域项目(17411954200),上海市科学与技术委员会医学引导类项目(18411967200),上海市卫生和计划生育委员会科研课题(201840215),上海市临床重点专科项目(shslczdzk03501).
摘    要:目的:探讨超声造影技术(contrast-enhanced ultrasound,CEUS)联合高频线阵超声探头对胆囊内蛔虫残骸和肿瘤性病变的鉴别诊断价值。方法:回顾性分析2015年6月至2018年6月复旦大学附属中山医院收治的9例胆囊内蛔虫残骸患者和20例经手术证实胆囊内肿瘤患者的超声造影表现。根据EFSUMB超声造影指南,鉴别比较2组患者常规超声和高频超声造影表现。结果:胆囊内蛔虫残骸与胆囊低回声肿瘤在二维超声上,都表现为低回声不均质实质占位。但所有胆囊内蛔虫残骸在高频超声造影各个时期都未见明显增强,而胆囊肿瘤都表现为一定程度的增强-消退改变。结论:高频超声造影凭借实时显像、安全简便等优势,可敏感、准确地鉴别胆囊内蛔虫残骸和胆囊内实质性肿瘤。

关 键 词:胆囊  蛔虫残骸  超声造影  肿瘤  鉴别诊断
收稿时间:2020/2/27 0:00:00
修稿时间:2020/8/13 0:00:00

Diagnostic value of high-frequency contrast-enhanced ultrasound in the ascaris debris in the gallbladder
XU Ben-hu,DONG Yi,ZHANG Qi,YANG Dao-hui,QIU Yi-jie,WANG Wen-ping.Diagnostic value of high-frequency contrast-enhanced ultrasound in the ascaris debris in the gallbladder[J].Chinese Journal Of Clinical Medicine,2020,27(6):1017-1019.
Authors:XU Ben-hu  DONG Yi  ZHANG Qi  YANG Dao-hui  QIU Yi-jie  WANG Wen-ping
Institution:Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China
Abstract:Objective:To explore the value of contrast-enhanced ultrasound (CEUS) combined with high-frequency linear ultrasound probe for the differential diagnosis of ascaris debris and neoplasm of the gallbladder.Methods:The contrast-enhanced ultrasound findings of 9 patients with ascaris debris and 20 patients with neoplasia of the gallbladder confirmed by surgery in Zhongshan Hospital, Fudan University from June 2015 to June 2018 were retrospectively analyzed. Results of the conventional B-mode ultrasound (BMUS) and CEUS enhancement pattern of the lesions were compared and analyzed according to the current EFSUMB guidelines.Results:The ascaris debris in the gallbladder and the hypoechoic tumor of the gallbladder were both characterized by hypoechoic heterogeneous solid occupation on BMUS. The signals of all pieces of ascaris debris in the gallbladder were not significantly enhanced during each phase of CEUS. However, gallbladder tumors present with some degree of enhancement-regression changes at each phase of CEUS.Conclusion: Depending on the advantages of being real-time, safe and simple, CEUS can sensitively and accurately distinguish the ascaris debris and solid neoplasm in the gallbladder.
Keywords:gallbladder  ascaris debris  contrast-enhanced ultrasound  neoplasm  differential diagnosis