接触型电烧伤患者入院早期心肌酶谱与常见临床因素的相关性
引用本文:雷少军,张晶晶,闫利.接触型电烧伤患者入院早期心肌酶谱与常见临床因素的相关性[J].武警医学,2019,30(9):749-751.
作者姓名:雷少军  张晶晶  闫利
作者单位:300162 天津,武警特色医学中心:1.烧伤整形外科,2.妇产科
基金项目:天津市卫生局科技基金(2014KZ136)
摘    要: 目的 分析接触型电烧伤患者入院早期心肌酶谱与常见临床因素的相关性。方法 选取武警特色医学中心2008-2018年收治的接触型电烧伤患者107例,将患者入院早期CK、CK-MB、LDH检测数值与患者致伤电压、年龄、入院时间、烧伤指数、烧伤部位数量进行二元变量相关分析。结果 患者CK与致伤电压、烧伤指数、烧伤部位数量呈正相关(r=0.400、0.614、0.465,P值均小于0.05),与年龄、入院时间无明显相关关系(r=-0.042、-0.146,P值均大于0.05);患者CK-MB与致伤电压、烧伤指数、烧伤部位数量呈正相关(r=0.348、0.578、0.510,P值均小于0.05),与年龄、入院时间无明显相关关系(r=-0.110、-0.071,P值均大于0.05);患者LDH与致伤电压、烧伤指数、烧伤部位数量呈正相关(r=0.395、0.575、0.471,P值均小于0.05),与年龄、入院时间无明显相关关系(r=-0.193、-0.255,P值均大于0.05)。结论 烧伤指数是影响接触型电烧伤患者入院早期CK、CK-MB、LDH更明显的因素,烧伤部位数量是影响接触型电烧伤患者入院早期CK-MB更明显的因素。

关 键 词:电烧伤  心肌酶  影响因素  相关分析  
收稿时间:2019-03-11

Relationships between myocardial enzymes and common clinical factors in patients with contact electric burn soon after admission
LEI Shaojun,ZHANG Jingjing,YAN Li.Relationships between myocardial enzymes and common clinical factors in patients with contact electric burn soon after admission[J].Medical Journal of the Chinese People's Armed Police Forces,2019,30(9):749-751.
Authors:LEI Shaojun  ZHANG Jingjing  YAN Li
Institution:1. Burn Plastic Surgery, 2. Obstetrics and Gynecology Department, Armed Police Characteristic Medical Center, Tianjin 300162, China
Abstract:Objective To analyze the correlations between myocardial enzymes and common clinical factors in patients with contact electric burn soon after admission.Methods One hundred and seven cases of contact electric burn patients admitted to Armed Police Medical Center between 2008 and 2018 were selected. The detection values of CK, CK-MB and LDH in the early days of admission were correlated with the injury voltage, age, admission time, burn indexes and the number of burn sites.Results CK was positively correlated with injury voltage, burn indexes and numbers of burn sites (r=0.400, 0.614, 0.465, P value was less than 0.05), but not with age and admission time (r=-0.042,-0.146, P value was greater than 0.05), so were CK-MB (r=0.348, 0.578, 0.510, P value was less than 0.05) and LDH (r=0.395, 0.575, 0.471, P value was less than 0.05).Conclusions The burn index is a more significant factor affecting the early detection of CK, CK-MB and LDH in patients with contact electrical burn. The number of burn sites is a more significant factor affecting the early detection of CK-MB in patients with contact electrical burn.
Keywords:electrical burn  myocardial enzymes  influencing factors  correlation analysis  