双侧长度对比法测量锁骨中段骨折短缩程度的准确性及应用价值
引用本文:沙一帆,王秋根,罗倩,王琦,吴晓明. 双侧长度对比法测量锁骨中段骨折短缩程度的准确性及应用价值[J]. 中华肩肘外科电子杂志, 2020, 8(2): 125-134. DOI: 10.3877/cma.j.issn.2095-5790.2020.02.006
作者姓名:沙一帆  王秋根  罗倩  王琦  吴晓明
作者单位:1. 200080 上海市第一人民医院创伤骨科2. 200080 上海市第一人民医院放射科
基金项目:国家自然科学基金重大面上项目(71432007)
摘    要:目的研究双侧长度对比法(对比法)测量锁骨中段骨折短缩程度的准确性及应用价值。 方法建立在术后锁骨骨折解剖复位的前提上,以校准法作为标准,分析伤时对比法的准确性,将对比法对同批患者采用不同摄片方式:前后位(posterioranterior,PA)正位、后前位(anteriorposterior,AP)15°头倾位、PA15°尾倾位测得并计算出的锁骨短缩值(双侧)与校准法计算出的锁骨短缩值(校准)进行Bland-Altman一致性分析。 结果3种摄片方式,对比法比校准法误差的95%一致性界限范围为:PA正位-10.98 ~ 10.00 mm,AP15°头倾位-18.98 ~ 10.95 mm,PA15°尾倾位-18.93 ~ 13.88 mm,3种摄片方式中PA正位误差相对较小,d绝对值由小到大排列为:PA正位(4.22 mm)15 mm的共5例,这5例用校准法相同摄片方式测得>15 mm仅1例,符合率20%;应用校准法测得锁骨缩短值>15 mm的共10例,这10例用对比法相同摄片方式测得锁骨缩短值>15 mm仅1例,符合率10%。 结论应用对比法测量锁骨短缩程度(摄片方式PA正位、AP15°头倾位、PA15°尾倾位)误差很大,准确性不够,不适用于锁骨中段骨折手术指征的判断。在常用的锁骨摄片方式中,PA正位对比法测量出的锁骨短缩值更接近于真实值。

关 键 词:锁骨中段骨折  双侧长度对比法  一致性分析  
收稿时间:2019-06-16

Accuracy and application value of bilateral length comparison method in the assessment of shortening degree after mid-shaft clavicular fracture
Yifan Sha,Qiugen Wang,Qian Luo,Qi Wang,Xiaoming Wu. Accuracy and application value of bilateral length comparison method in the assessment of shortening degree after mid-shaft clavicular fracture[J]. Chinese Journal of Shoulder and Elbow (Electronic Edition), 2020, 8(2): 125-134. DOI: 10.3877/cma.j.issn.2095-5790.2020.02.006
Authors:Yifan Sha  Qiugen Wang  Qian Luo  Qi Wang  Xiaoming Wu
Affiliation:1. Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai 200080, China
Abstract:BackgroundAfter acute mid-shaft clavicular fracture, the shortening degree is one of the relative indication for surgery. When shortening distance is over 15 to 20 mm, the surgery is necessary. It is important to accurately measure the shortening degree of clavicular fracture in the absence of open fractures with absolute indications such as vascular and nerve injury. It is difficult to measure the shortening degree of clavicle accurately on the X-ray film because of its S-shape, and different angles on the X-ray films make the test results variable. Which is the optimal measurement method is still controversial, and thus it brings difficulty to make appropriate treatment plan. ObjectiveTo investigate and compare the accuracy and application value of bilateral length comparison method in the assessment of shortening degree after mid-shaft clavicular fracture. MethodsBased on the premise of anatomic reduction of postoperative clavicle fracture, the accuracy of bilateral clavicle length comparison method (bilateral method) was analyzed with the calibration method as the standard. The bilateral method was used to take different films for the same group of patients, including posteroanterior (PA) view, anteroposterior (AP) 15° cephalad view, and posteroanterior (PA) 15° caudal view. Bland-altman consistency analysis was performed for the measured and calculated collarbone shrinkage (bilateral) and the calculated collarbone shrinkage (calibration) . ResultsWith the 3 methods, the 95% consistency range of error of bilateral length comparison method compared with calibration method is -10.98 ~ 10.00 mm of PA view, -18.98 ~ 10.95 mm of AP 15° cephalad view and -18.93 ~ 13.88 mm of PA 15° caudal view respectively. Among these methods, the PA view had the smallest error relatively. The dabsolute value ranged from small to large were 4.22 mm on PA view, 6.53 mm on
Keywords:Mid-shaft clavicular fracture  Bilateral clavicle length comparison method  Coherence analysis  