首页 | 本学科首页   官方微博 | 高级检索  
检索        


Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions
Authors:Mihai Strachinaru  Chris M Kievit  Sing C Yap  Alexander Hirsch  Marcel L Geleijnse  Tamas Szili‐Torok
Abstract:Both transesophageal echocardiography (TEE) and intracardiac echocardiography have been used to assist transvenous lead extractions. The clinical utility of continuous echocardiographic monitoring during the procedure is still debated, with different reports supporting opposite findings. In cases where the procedure is expected to be difficult, we propose adding a continuous TEE monitoring using a static 3D/multiplane probe in mid‐esophageal position, with digital remote manipulation of the field of view. This approach may improve the chances of a successful extraction, increase safety, or even guide the entire intervention. We present here a short case series where continuous monitoring by TEE played an important role.
Keywords:continuous echocardiography monitoring  intraprocedural echocardiography  multiplane echocardiography  transesophageal echocardiography  transvenous lead extraction
设为首页 | 免责声明 | 关于勤云 | 加入收藏