Stability of Cefazolin in Polyisoprene Elastomeric Infusion Devices
Authors:Rahul P Patel  Jilson Jacob  Mohammed Sedeeq  Long Chiau Ming  Troy Wanandy  Syed Tabish R Zaidi  Gregory M Peterson
Institution:1. Division of Pharmacy, School of Medicine, University of Tasmania, Hobart, Tasmania, Australia;2. School of Pharmacy, KPJ Healthcare University College, Nilai, Malaysia;3. Department of Pharmacy and Jack Jumper Allergy Program, Royal Hobart Hospital, Hobart, Tasmania, Australia
Abstract:

Purpose

The aim was to investigate the stability of cefazolin in elastomeric infusion devices.

Methods

Elastomeric devices (Infusor LV) that contain cefazolin (3 g/240 mL and 6 g/240 mL) were prepared and stored at 4°C for 72 hours and then at 35°C for 12 hours, followed by 25°C for 12 hours. An aliquot was withdrawn at predefined time points and analyzed for the concentration of cefazolin. Samples were also assessed for changes in pH, solution color, and particle content.

Findings

Cefazolin retained acceptable chemical and physical stability over the studied storage period and conditions.

Implications

These findings will allow the administration of cefazolin by the Infusor LV elastomeric device in the outpatient and remote settings.
Keywords:cefazolin  continuous infusion  elastomeric device  high-performance liquid chromatography  infective endocarditis  stability