首页 | 本学科首页   官方微博 | 高级检索  
     

LA MP结合示差脉冲伏安法快速检测肺炎克雷伯菌的方法建立及临床应用
引用本文:刘孝波,蒋栋能,项贵明,蒲晓允. LA MP结合示差脉冲伏安法快速检测肺炎克雷伯菌的方法建立及临床应用[J]. 国外医学:临床生物化学与检验学分册, 2014, 0(12): 1539-1541
作者姓名:刘孝波  蒋栋能  项贵明  蒲晓允
作者单位:第三军医大学第二附属医院检验科,重庆400037
基金项目:重庆市科技攻关重点项目(CSTC2011AB5035).
摘    要:目的:利用环介导恒温扩增(LAMP)技术结合示差脉冲伏安(DPV)法,建立快速检测肺炎克雷伯菌的方法,并将其应用于小儿腹泻病原菌分析。方法通过基因比对与引物设计,建立针对肺炎克雷伯菌的LAMP 检测方法。采用LAMP 技术对肺炎克雷伯菌和其他8种干扰菌以及对不同浓度肺炎克雷伯菌进行扩增,结合DPV法评价其特异性及灵敏度。将200份腹泻患儿的粪便标本同时采用LAMP方法与培养法进行检验,对比2种方法检测肺炎克雷伯菌的阳性率。统计近2年该院门诊及住院小儿腹泻病例,初步分析其常见腹泻致病菌种类及比例。结果设计出针对肺炎克雷伯菌的LAMP 检测方法,该法只针对肺炎克雷伯菌有扩增,对其他干扰菌不扩增,显示出良好的特异性,LAMP法最低检测限为10 CFU/mL,显示出较高的灵敏度。200份腹泻患儿粪便标本,采用LAMP法与培养鉴定法检测的肺炎克雷伯菌阳性率差异无统计学意义(P>0.05)。近2年内该院小儿腹泻粪便标本中共检出致病菌709株,主要病原菌分别为志贺菌(34.23%)、大肠杆菌(15.40%)、铜绿假单胞菌(12.96%)、弗劳地枸橼酸杆菌(7.82%)、沙门菌(6.36%)、白色念珠菌(6.11%)、肺炎克雷伯菌(4.40%)、产气荚膜梭菌(3.67%)、变形杆菌(3.42%)、其他菌(5.63%)。结论设计出了针对肺炎克雷伯菌的LAMP检测方法,该法具有良好的特异性和较高的灵敏度,能够用于肺炎克雷伯菌的快速检验。

关 键 词:环介导恒温扩增  示差脉冲伏安法  肺炎克雷伯菌  快速检验  细菌性肠炎

Rapid detection of Kldbsidlla pndumoniad based on loop-mediated isothermal amplification with differential pulse voltammetry
LiuXiaobo,JiangDongneng,XiangGuiming,PuXiaoyun. Rapid detection of Kldbsidlla pndumoniad based on loop-mediated isothermal amplification with differential pulse voltammetry[J]. Foreign Medical Sciences(section of Clinical Biochemistry and Laboratory Medicine, 2014, 0(12): 1539-1541
Authors:LiuXiaobo  JiangDongneng  XiangGuiming  PuXiaoyun
Affiliation:(Department of Clinical Laboratory ,the Second Affiliated Hospital of the Third Military Medical University, Chongqing 400037, China)
Abstract:Objective To construct method based on loop-mediated isothermal amplification (LAMP)and differential pulse vol-tammetry (DPV)for the rapid detection of Klebsiellapneumoniae in children with diarrhea.Methods By gene alignment and prim-er design,LAMP method for the detection of Klebsiella pneumoniae was constructed.Klebsiella pneumoniae,other 8 kinds of in-terference bacteria and different concentration of Klebsiella pneumoniae were amplified by using LAMP technology.Specificity and sensitivity were evaluated by using DPV method.LAMP and culture identification were performed to analyze 200 stool samples of children with diarrhea,and the positive rates of the two methods were compared.Infantile diarrhea cases of outpatient and inpatient in recent two years were analyzed to identify common diarrhea bacteria species and their proportions.Results LAMP method for detection of Klebsiella pneumoniae was successfully constructed,which was specific and sensitive.Positive rates of culture identifi-cation and LAMP for the detection of 200 stool samples were without significant difference.A total of 709 strains of pathogenic bacteria were detected in stool samples of children with diarrhea treated in this hospital in recent two years,including Shigella (34.23%),Escherichia coli (15.40%),Pseudomonas aeruginosa (12.96%),Citrobacter freundii (7.82%),Salmonella (6.36%),Candida albicans (6.11%),Klebsiella pneumoniae (4.40%),Clostridium perfringens (3.67%),Bacillus proteus (3.42%)and other strains (5.63%).Conclusion LAMP detection method of Klebsiella pneumoniae was successfully construc-ted,which was with fine specificity and sensitivity,and could be used for rapid detection of Klebsiella pneumoniae.
Keywords:loop-mediated isothermal amplification  differential pulse voltammetry  Klebsiella pneumoniae  rapid detec-tion  bacterial enteritis