首页 | 本学科首页   官方微博 | 高级检索  
检索        


Negative flecainide test in Brugada syndrome patients with previous positive response.
Authors:Mauricio Abello  José L Merino  Rafael Peinado  Mariana Gnoatto
Institution:Laboratory of Clinical Cardiac Electrophysiology, Division of Cardiology, La Paz University Hospital, Paseo de la Castellana 261, 28046 Madrid, Spain.
Abstract:Class I antiarrhythmic drug infusion has been established as the standard test to unmask Brugada syndrome. This report presents two patients with Brugada syndrome with positive flecainide response which was not reproducible in a subsequent test.
Keywords:Flecainide  Brugada syndrome  Electrocardiogram
本文献已被 Oxford 等数据库收录!