首页 | 本学科首页   官方微博 | 高级检索  
检索        


3D Isotropic Super-resolution Prostate MRI Using Generative Adversarial Networks and Unpaired Multiplane Slices
Authors:Liu  Yucheng  Liu  Yulin  Vanguri  Rami  Litwiller  Daniel  Liu  Michael  Hsu  Hao-Yun  Ha  Richard  Shaish  Hiram  Jambawalikar  Sachin
Institution:1.Department of Radiology, Columbia University Irving Medical Center, 622 W 168 11th St, New York, NY, USA
;2.Department of Information and Computer Engineering, Chung Yuan Christian University, Chung Li District, 200 Chung Pei Road, Taoyuan City, Taiwan
;3.Computational Oncology Service, Department of Epidemiology & Biostatistics, Memorial Sloan, Kettering Cancer Center 485 Lexington Ave, New York, NY, 10017, USA
;4.Global MR Applications and Workflow, GE Healthcare, New York, NY, USA
;
Abstract:

We developed a deep learning–based super-resolution model for prostate MRI. 2D T2-weighted turbo spin echo (T2w-TSE) images are the core anatomical sequences in a multiparametric MRI (mpMRI) protocol. These images have coarse through-plane resolution, are non-isotropic, and have long acquisition times (approximately 10–15 min). The model we developed aims to preserve high-frequency details that are normally lost after 3D reconstruction. We propose a novel framework for generating isotropic volumes using generative adversarial networks (GAN) from anisotropic 2D T2w-TSE and single-shot fast spin echo (ssFSE) images. The CycleGAN model used in this study allows the unpaired dataset mapping to reconstruct super-resolution (SR) volumes. Fivefold cross-validation was performed. The improvements from patch-to-volume reconstruction (PVR) to SR are 80.17%, 63.77%, and 186% for perceptual index (PI), RMSE, and SSIM, respectively; the improvements from slice-to-volume reconstruction (SVR) to SR are 72.41%, 17.44%, and 7.5% for PI, RMSE, and SSIM, respectively. Five ssFSE cases were used to test for generalizability; the perceptual quality of SR images surpasses the in-plane ssFSE images by 37.5%, with 3.26% improvement in SSIM and a higher RMSE by 7.92%. SR images were quantitatively assessed with radiologist Likert scores. Our isotropic SR volumes are able to reproduce high-frequency detail, maintaining comparable image quality to in-plane TSE images in all planes without sacrificing perceptual accuracy. The SR reconstruction networks were also successfully applied to the ssFSE images, demonstrating that high-quality isotropic volume achieved from ultra-fast acquisition is feasible.

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号