首页 | 本学科首页   官方微博 | 高级检索  
检索        

清开灵注射液中重金属及有害元素的质量控制
引用本文:施晓光,陆敏仪,赵庄,刘华钢,甘盛,戴向东,许杨彪.清开灵注射液中重金属及有害元素的质量控制[J].中国实验方剂学杂志,2013,19(6):75-77.
作者姓名:施晓光  陆敏仪  赵庄  刘华钢  甘盛  戴向东  许杨彪
作者单位:广西壮族自治区食品药品检验所,南宁 530021;广西壮族自治区食品药品检验所,南宁 530021;广西壮族自治区食品药品检验所,南宁 530021;广西壮族自治区食品药品监督管理局,南宁 530021;广西壮族自治区食品药品检验所,南宁 530021;广西壮族自治区食品药品检验所,南宁 530021;广西壮族自治区食品药品检验所,南宁 530021
基金项目:国家科技重大专项(2009ZX09308-006);科技部十一五支撑项目(2008BAI55B02)
摘    要:目的:探索用电感耦合等离子体质谱法测定清开灵注射液的铅、砷、铜、镉、汞,探讨其中重金属及有害元素的质量控制。方法:清开灵注射液经微波消解后,加入Sc,In,Ge,Bi等内标元素,以茶叶作为质控标准物质,注入电感耦合等离子体质谱仪测定样品中铅、砷、铜、镉、汞的含量。结果:标准曲线相关系数r>0.997,回收率为93.2%~100.3%,RSD<2.7%。结论:方法准确迅速,操作性强,干扰少,可以用于清开灵注射液中重金属及有害元素的质量控制。

关 键 词:清开灵注射液  重金属及有害元素  质量控制
收稿时间:2012/6/10 0:00:00

Quality Control of Heavy Metal and Hazard Elements in Efficacious on Heat Expelling and Enlightening Injection
SHI Xiao-guang,LU Min-yi,ZHAO Zhuang,LIU Hua-gang,GAN Sheng,DAI Xiang-dong and XU Yang-biao.Quality Control of Heavy Metal and Hazard Elements in Efficacious on Heat Expelling and Enlightening Injection[J].China Journal of Experimental Traditional Medical Formulae,2013,19(6):75-77.
Authors:SHI Xiao-guang  LU Min-yi  ZHAO Zhuang  LIU Hua-gang  GAN Sheng  DAI Xiang-dong and XU Yang-biao
Institution:Guangxi Institute for Food and Drug Control, Nanning 530021, China;Guangxi Institute for Food and Drug Control, Nanning 530021, China;Guangxi Institute for Food and Drug Control, Nanning 530021, China;Guangxi Food and Drug Administration, Nanning 530021, China;Guangxi Institute for Food and Drug Control, Nanning 530021, China;Guangxi Institute for Food and Drug Control, Nanning 530021, China;Guangxi Institute for Food and Drug Control, Nanning 530021, China
Abstract:Objective: To approach the quantitative determination of Pb, As, Cu, Cd and Hg in efficacious on Heat Expelling and Enlightening Injection by inductively coupled plasma mass spectrometry.To probe into the quality control of heavy metal and hazard elements in Efficacious on Heat Expelling and Enlightening Injection. Method: The samples, digested via microwave, calibrated by internal standard elements such as Sc, In, Ge and Bi, with tea leaves as the controlled reference standard, were inlet into ICP-MS to analyze the quantity of Pb, As, Cu, Cd and Hg. Result: The correlative coefficients of the standard curves surpasses 0.997, with the recovery at 93.2%-100.3%, while their RSD was below 2.7%. Conclusion: The method is proved to be accurate and fast, seldom interfered, consultable for quality control of heavy metal and hazard elements in Efficacious on Heat Expelling and Enlightening Injection.
Keywords:Efficacious on Heat Expelling and Enlightening Injection  heavy metal and hazard elements  quality control
本文献已被 CNKI 等数据库收录!
点击此处可从《中国实验方剂学杂志》浏览原始摘要信息