首页 | 本学科首页   官方微博 | 高级检索  
检索        

腹腔镜全子宫切除术中结扎束血管闭合系统的应用研究
引用本文:边立华,王楠,范文生,叶明侠,王敏,孟元光.腹腔镜全子宫切除术中结扎束血管闭合系统的应用研究[J].中华腔镜外科杂志(电子版),2016,9(6):358-361.
作者姓名:边立华  王楠  范文生  叶明侠  王敏  孟元光
作者单位:1. 100853 北京,解放军总医院妇产科
基金项目:国家自然科学基金(81571411)
摘    要:目的评估结扎束血管闭合系统(LF1537 Blunt Tip)在腹腔镜全子宫切除术中应用的临床疗效,探讨其临床价值。 方法选取解放军总医院2014年1月至2016年1月期间收治并行腹腔镜全子宫切除术患者,根据术中是否使用结扎束血管闭合系统分为观察组(使用结扎束血管闭合系统)和对照组(常规手术),记录并比较两组的一般资料和手术相关指标。 结果两组的年龄、体质量指数、腹部手术史符合正态分布且差异无统计学意义(P=0.625、0.287、0.664);两组的疾病构成差异无统计学意义(P=0.808)。观察组的手术时间(46.6 ± 19.1)min vs (65.8 ± 29.2)min]和术中出血量(51.0 ± 21.9)ml vs (118.4 ± 50.7)ml]均少于对照组,差异有统计学意义(P< 0.001);两组的输血(2例 vs 6例)、住院时间(6.3 ± 2.2)d vs (6.7 ± 2.8) d]、中转开腹(0例 vs 2例)、并发症发生(4例 vs 7例)比较,差异无统计学意义(P=0.204、0.391、0.182、0.472)。 结论本研究中将结扎束血管闭合系统(LF1537 Blunt Tip)应用于腹腔镜全子宫切除术,能够更加安全有效的对血管和组织进行闭合和切割,缩短了手术时间,减少了出血量,使手术更加可靠、快捷,具有重要临床应用价值。

关 键 词:腹腔镜全子宫切除术  结扎束  血管闭合系统  能量器械  
收稿时间:2016-09-06

Application of ligasure vessel sealing system in laparoscopic total hysterectomy
Lihua Bian,Nan Wang,Wensheng Fan,Mingxia Ye,Min Wang,Yuanguang Meng.Application of ligasure vessel sealing system in laparoscopic total hysterectomy[J].Chinese Journal of Laparoscopic Surgery ( Electronic Editon),2016,9(6):358-361.
Authors:Lihua Bian  Nan Wang  Wensheng Fan  Mingxia Ye  Min Wang  Yuanguang Meng
Institution:1. Department of Obstetrics and Gynecology, Chinese PLA General Hospital, Beijing 100853, China
Abstract:ObjectiveTo evaluate the clinical effect of Ligasure Vessel Sealing System (LF1537 Blunt Tip) in laparoscopic total hysterectomy and to explore its clinical value. MethodsAll patients selected in our hospital during the period of Jan. 2014 to Jan. 2016 undergoing laparoscopic total hysterectomy were analyzed. All cases were divided into observation group (using ligasure group) and control group (conventional surgery group). The general information and the operation related index were compared between the two groups. ResultsThe mean age, BMI, history of previous abdominal surgery in the two groups were in the normal distribution and the difference was not statistically significant (P=0.625, 0.287, 0.664). The difference of disease constitute of the two groups was not statistically significant (P=0.808). In the observation group, the average operation time (46.6 ± 19.1) min vs (65.8 ± 29.2) min]and the blood loss (51.0 ± 21.9) ml vs (118.4 ± 50.7)ml] during operation were lower than that in the control group. There were no significant difference in the rate of blood transfusion (2 cases vs 6 cases), average length of stay (6.3 ± 2.2)d vs (6.7 ± 2.8) d], rate of conversion to laparotomy (0 case vs 2 cases), and the incidence of complications (4 cases vs 7 cases) between the two groups (P=0.204, 0.391, 0.182, 0.472). ConclusionsIn this study, Blunt Tip LF1537 was used in laparoscopic total hysterectomy. It can be more safe and effective for the vascular and tissue closure and cutting, shorten the operation time, reduce the amount of bleeding, so that the operation is more reliable and fast.
Keywords:Laparoscopic total hysterectomy  Ligasure  Vessel sealing system  Energy instrument  
本文献已被 CNKI 等数据库收录!
点击此处可从《中华腔镜外科杂志(电子版)》浏览原始摘要信息
点击此处可从《中华腔镜外科杂志(电子版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏