首页 | 本学科首页   官方微博 | 高级检索  
检索        


Differences between cytotoxicity in photodynamic therapy using a pulsed laser and a continuous wave laser: study of oxygen consumption and photobleaching
Authors:S?Kawauchi  Email author" target="_blank">Y?MorimotoEmail author  S?Sato  T?Arai  K?Seguchi  H?Asanuma  M?Kikuchi
Institution:(1) Department of Medical Engineering, National Defense Medical College, 3-2 Namiki, Tokorozawa, 359-8513 Saitama, Japan;(2) Division of Biomedical Information Sciences, National Defense Medical College Research Institute, 3-2 Namiki, Tokorozawa, 359-8513 Saitama , Japan;(3) Department of Applied Physics and Physico-Informatics, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, , Kouhoku-ku, 223-8522 Yokohama , Japan;(4) Department of Urology, National Defense Medical College, 3-2 Namiki, Tokorozawa, 359-8513 Saitama , Japan;(5) Department of Urology, Tokyo Metropolitan Kiyose Childrenrsquos Hospital, 1-3-1 Umezono, Kiyose, 204-0024 Tokyo, Japan
Abstract:Oxygen consumption at the targeted site has a significant effect on dosimetry in photodynamic therapy (PDT). However, oxygen consumption in PDT using a pulsed laser as a light source has not been clarified. We therefore investigated the dependence of cytotoxicity on the oxygen consumption and the photosensitizer photobleaching of PDT using a pulsed laser by comparing with that using a continuous wave (CW) laser. Mouse renal carcinoma cells (Renca) were incubated with a second-generation photosensitizer, PAD-S31. The cells were then irradiated with either a 670-nm nanosecond pulsed light from the 3rd harmonics of a Nd:YAG laser-pumped optical parametric oscillator with a peak fluence rate of ~1 MW/cm2 at 30 Hz or a 670-nm CW diode laser with a total light dose of 40 J/cm2. Regardless of laser source, cytotoxic effects exhibited cumulative dose responses to the photosensitizer ranging from 12 to 96 mgrg/ml. However, cytotoxic effect of PDT using the pulsed light was significantly less than that using the CW light with the photosensitizer concentrations of 24 and 48 mgrg/ml under identical fluence rates. During PDT, the cells exposed to the pulsed light consumed oxygen more slowly, resulting in a lower amount of oxygen consumption when compared with PDT using CW light. In accordance with oxygen consumption, the pulsed light induced significantly less photobleaching of the photosensitizer than the CW light did. These results indicate that the efficiency of PDT using pulsed light is less when compared with CW light, probably being related to suppressed oxygen consumption during the pulsed light irradiation.
Keywords:Nanosecond pulsed light  Oxygen measurement  PAD-S31  Photodynamic therapy
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏