首页 | 本学科首页   官方微博 | 高级检索  
     


Quantification of aortic regurgitation by Doppler echocardiography: a new method evaluated in pigs
Authors:S. A. Slørdahl  J. E. Solbakken  H. Piene  B. A. J. Angelsen  O. Rossvoll  S. O. Samstad
Affiliation:(1) Department of Biomedical Engineering, University of Trondheim, 7006 Trondheim, Norway
Abstract:We have developed a method to quantify aortic regurgitant orifice and volume, based on measurements of the velocity of the regurgitant jet, aortic systolic flow, the systolic and diastolic arterial pressures, a Windkessel arterial model, and a parameter estimation technique. In six pigs we produced aortic regurgitant flows between 2·1 and 17·8 ml per beat, i.e. regurgitant fractions from 0·06 to 0·58. Pulmonary and aortic flows were measured with electromagnetic flow probes, aortic pressure was measured invasively, and the regurgitant jet velocity was obtained with continuous-wave Doppler. The parameter estimation procedure was based on the Kalman filter principle, resulting primarily in an estimate of the regurgitant orifice area. The area was multiplied by the velocity integral of the regurgitant jet to estimate regurgitant volume. A strong correlation was found between the regurgitant volumes obtained by parameter estimation and the electromagnetic flow measurement. These results from our study in pigs suggest that it may be possible to quantify regurgitant orifice and volume in patients completely noninvasively from Doppler and blood pressure measurements.
Keywords:Aortic regurgitation  Doppler ultrasound  Electromagnetic flow probes  Parameter estimation  Regurgitant orifice  Regurgitant volume  Windkessel model
本文献已被 SpringerLink 等数据库收录!