Detection of human rotavirus by nucleic acid analysis in comparison to enzyme-linked immunoassay and electron microscopy
Authors:B. Selb  H. G. Baumeister  G. Maass  H. W. Doerr
Affiliation:1. Department of Medical Virology, University Clinic of Heidelberg, Im Neuenheimer Feld 324, 6900, Heidelberg 1, FRG
2. State Institute of Diagnostic Virology, Nordrhein-Westfalen, von-Stauffenberg-Str. 36, 4400, Münster, FRG
3. Department of Medical Virology, Centre of Hygiene, University Clinics of Frankfurt, Paul-Ehrlich-Str. 40, 6000, Frankfurt 70, FRG
Abstract:The results of RNA analysis for the detection of rotavirus were compared with those of a standard enzyme-linked immunsorbent assay (ELISA) and electron microscopy using 212 faecal specimens obtained from 200 children with gastroenteritis. Rotavirus was extracted directly from faecal specimens and RNA segments were made visible by polyacrylamide gel electrophoresis using a silver staining technique. Of the 212 faecal specimens 137 were found to be positive in ELISA, 125 in RNA analysis and 121 in both methods. Forty-nine of the 212 specimens were also investigated by electron microscopy. Thirty-five were positive when examined by electron microscopy, 37 were positive in ELISA and 33 in RNA analysis. RNA analysis of 119 faecal samples in outbreaks and sporadic cases of rotavirus infection yielded 42 different rotavirus electrophoretypes. The results indicated that no one method was sufficient to detect all positive specimens and that RNA analysis is useful in epidemiological studies.
Keywords:
本文献已被 SpringerLink 等数据库收录!