An unusual complication of tubal anastomosis |
| |
Authors: | Jurema Marcus W Vlahos Nikos P |
| |
Affiliation: | Division of Reproductive Endocrinology, The Johns Hopkins Medical Institutions, Baltimore, Maryland 21287, USA. |
| |
Abstract: | OBJECTIVE: To report an unusual complication associated with the use of a long-term intrafallopian stent during microsurgical tubal anastomosis. DESIGN: Case report. SETTING: Tertiary academic center. PATIENT(S): A 36-year-old woman in whom an intrafallopian stent used during a sterilization reversal procedure could not be transcervically retrieved in the office. INTERVENTION(S): Hysteroscopic evaluation for removal of intrafallopian stent, followed by operative laparoscopy for postoperative abdominal pain. MAIN OUTCOME MEASURE(S): Patient symptoms, potential for morbidity, and review of the literature. RESULT(S): Hysteroscopic view of the uterine cavity failed to identify the intrafallopian stent. Laporoscopic evaluation of postoperative abdominal pain revealed significant formation of pelvic and abdominal adhesions. The 2-0 nylon suture used as an intrafallopian stent was seen sitting freely on top of the liver serosa. Adhesiolysis and successful retrieval of the stent resolved the patient's symptoms. CONCLUSION(S): To our knowledge, this is the first report describing complete dislodgment and cephalad migration of an intrafallopian stent. Patient morbidity and health care costs may increase when long-term stents are used for sterilization reversal. |
| |
Keywords: | tubal anastomosis sterilization reversal fallopian tube stent |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|