首页 | 本学科首页   官方微博 | 高级检索  
     


What is the most appropriate energy source for aortic cusp ablation? A comparison of standard RF, cooled-tip RF and cryothermal ablation
Authors:Andre d’Avila  Aravinda Thiagalingam  Godtfred Holmvang  Christopher Houghtaling  Jeremy N. Ruskin  Vivek Y. Reddy
Affiliation:(1) Cardiac Arrhythmia Service, Massachusetts General Hospital—Harvard Medical School, 55 Fruit Street/GRB 109, Boston, MA 02114, USA;(2) Cardiac MRI Unit, Massachusetts General Hospital—Harvard Medical School, 55 Fruit Street/GRB 109, Boston, MA 02114, USA
Abstract:Background Certain tachycardias can be eliminated by catheter ablation from within the base of the aortic valve (AV) cusps but the high blood flow and proximity to the coronary arteries create unique challenges. Standard radiofrequency (RF) energy, cooled-tip RF energy or cryothermal energy were compared to determine the optimal ablation modality.Materials and methods Experiments were conducted using adult swine or goats (15 animals). Ablation lesions were placed using either: temperature-controlled RF (4 mm-tip catheter; 60°C/60 s), cooled-tip RF (4 mm-tip catheter with internal saline circulation at 0.6 ml/s; 40°C/60 s), or cryoablation (6 mm-tip spot cryocatheter; <−75°C/4 min). Animals were sacrificed 1 h after the last application and lesions were subject to pathological analysis.Results Standard RF and cryoablation created similar depth lesions in the right coronary cusp (4.2±1.3 and 3.4±0.5 mm, respectively) but cryoablation was unable to create any visible lesions in the non-coronary cusp. Cooled tip ablation created larger ablation lesions in the right coronary cusp (5.25±0.5) and fully transmural left atrial ablation lesions after ablation in the noncoronary cusp. Acute damage to the cusps was not noted with any ablation modality. Disruption of elastic fibers in the aortic media was seen after standard and cooled tip radiofrequency ablation but not cryoablation.Conclusion Cryoablation within the AV cusps created similar sized lesions to standard RF ablation without evidence of elastic fibre disruption and may therefore be an appropriate first line ablation modality. Cooled-tip ablation created larger ablation lesions and therefore may be required if cryoablation is ineffective.This work was supported in part by an NIH K23 award (HL68064-02) to Dr. Reddy and by research grants from Boston Scientific, Inc and Cryocath Technologies, Inc.
Keywords:Ablation  Arrhythmia  Catheterization  Electrophysiology  Pericardium  Aorta  Cryoablation  Fibrillation
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号