首页 | 本学科首页   官方微博 | 高级检索  
     

微型种植体长度对骨界面应力分布的影响
引用本文:Shan LH,Dong FS,Gong WW,Zhang X. 微型种植体长度对骨界面应力分布的影响[J]. 华西口腔医学杂志, 2011, 29(1): 27-30. DOI: 10.3969/j.issn.1000-1182.2011.01.007
作者姓名:Shan LH  Dong FS  Gong WW  Zhang X
作者单位:1.河北医科大学第二医院口腔正畸科, 石家庄050000;2.河北医科大学口腔医院颌面外科, 石家庄050017; 3.清华大学工程力学系, 北京100084
基金项目:河北省科技支撑计划基金
摘    要:目的 探讨微型种植体长度对骨组织内应力分布的影响.方法建立直径1.6mm,长度分别为6、8、10、12 mm的种植体-下颌骨三维有限元模型,垂直植入种植体,给以1.96 N的水平向前及前上方向的载荷,记录并分析不同情况下的应力分布.结果 种植体水平向前载荷的应力峰值范围为3.500~3.765 MPa,位移峰值范围为1...

关 键 词:微型种植体  应力分布  三维有限元分析
收稿时间:2011-02-25
修稿时间:2011-02-25

The effect of mini-implant lengths on stress distributions in peri-implant surface
Shan Li-hua,Dong Fu-sheng,Gong Wei-wei,Zhang Xiong. The effect of mini-implant lengths on stress distributions in peri-implant surface[J]. West China journal of stomatology, 2011, 29(1): 27-30. DOI: 10.3969/j.issn.1000-1182.2011.01.007
Authors:Shan Li-hua  Dong Fu-sheng  Gong Wei-wei  Zhang Xiong
Affiliation:1. Dept. of Orthodontics, The Second Hospital, Hebei Medical University, Shijiazhuang 050000, China; 2. Dept. of Oral and Maxillofacial Surgery, Hospital of Stomatology, Hebei Medical University, Shijiazhuang 050017, China; 3. Dept. of Engineering Mechanics, Tsinghua University, Beijing 100084, China
Abstract:Objective To observe the effect of mini-implant lengths on stress distribution in peri-implant surface. Methods The 3D finite element analysis mandible and mini-implant models with diameter of 1.6 mm, lengths of 6, 8, 10 and 12 mm were established. The mini-implants were inserted into designed site of mandibular vertically, respectivly. A force of 1.96 N were applied mesioly and 45° tilted mesio-vertically in models. The stress distribution under every condition was recorded and analyzed. Results When load was applied mesially, the maximum stress varied from 3.500 to 3.765 MPa, the maximum displacement varied from 1.266 to 1.288 μm. When load was applied 45° tilted mesio-vertically, the maximum stress varied from 4.075 to 4.510 MPa, the maximum displacement varied from 1.668 to 1.694 μm. All of the maximum stress and displacement of loading mesially were lower than loading mesiovertically. Conclusion The change of the mini-implant length within 6-12 mm don’t show much influence on the stress distribution. The loading type is an important factor influencing stress and displacement of peri-implant bone.
Keywords:mini-implant  stress distribution  finite element analysis  
本文献已被 CNKI 万方数据 PubMed 等数据库收录!
点击此处可从《华西口腔医学杂志》浏览原始摘要信息
点击此处可从《华西口腔医学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号