首页 | 本学科首页   官方微博 | 高级检索  
     


The usefulness of F-18 FDG PET/CT-mammography for preoperative staging of breast cancer: comparison with conventional PET/CT and MR-mammography
Authors:Eun-Ha Moon  Seok Tae Lim  Yeon-Hee Han  Young Jin Jeong  Yun-Hee Kang  Hwan-Jeong Jeong  Myung-Hee Sohn
Affiliation:1.Department of Nuclear Medicine, Chonbuk National University Medical School and Hospital, Jeonju, Jeonbuk, Korea;2.Research Institute of Clinical Medicine, Chonbuk National University Medical School and Hospital, Jeonju, Jeonbuk, Korea;3.Department of Nuclear Medicine, Presbyterian Medical Center, Jeonju, Jeonbuk, Korea;4.Department of Nuclear Medicine, Dong-A University Medical Center, Busan, Korea;5.Department of Nuclear Medicine, Eulji University School of Medicine, Daejeon, Korea
Abstract:

Background

The objective of the study was to compare the diagnostic efficacy of an integrated Fluorine-18 fluorodeoxyglucose (F-18 FDG) PET/CT-mammography (mammo-PET/CT) with conventional torso PET/CT (supine-PET/CT) and MR-mammography for initial assessment of breast cancer patients.

Patients and methods

Forty women (52.0 ± 12.0 years) with breast cancer who underwent supine-PET/CT, mammo-PET/CT, and MR-mammography from April 2009 to August 2009 were enrolled in the study. We compared the size of the tumour, tumour to chest wall distance, tumour to skin distance, volume of axillary fossa, and number of meta-static axillary lymph nodes between supine-PET/CT and mammo-PET/CT. Next, we assessed the difference of focality of primary breast tumour and tumour size in mammo-PET/CT and MR-mammography. Histopathologic findings served as the standard of reference.

Results

In the comparison between supine-PET/CT and mammo-PET/CT, significant differences were found in the tumour size (supine-PET/CT: 1.3 ± 0.6 cm, mammo-PET/CT: 1.5 ± 0.6 cm, p < 0.001), tumour to thoracic wall distance (1.8 ± 0.9 cm, 2.2 ± 2.1 cm, p < 0.001), and tumour to skin distance (1.5 ± 0.8 cm, 2.1 ± 1.4 cm, p < 0.001). The volume of axillary fossa was significantly wider in mammo-PET/CT than supine-PET/CT (21.7 ± 8.7 cm3vs. 23.4 ± 10.4 cm3, p = 0.03). Mammo-PET/CT provided more correct definition of the T-stage of the primary tumour than did supine-PET/CT (72.5% vs. 67.5%). No significant difference was found in the number of metastatic axillary lymph nodes. Compared with MR-mammography, mammo-PET/CT provided more correct classification of the focality of lesion than did MR-mammography (95% vs. 90%). In the T-stage, 72.5% of cases with mammo-PET/CT and 70% of cases with MR-mammography showed correspondence with pathologic results.

Conclusions

Mammo-PET/CT provided more correct definition of the T-stage and evaluation of axillary fossa may also be delineated more clearly than with supine-PET/CT. The initial assessment of mammo-PET/CT would be more useful than MR-mammography because the mammo-PET/CT indicates similar accuracy with MR-mammography for decision of T-stage of primary breast tumour and more correct than MR-mammography for defining focality of lesion.
Keywords:breast cancer   fluorodeoxyglucose   positron emission tomography   MRI   mammography
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号