摘    要:[目的]调查分析某城市生活饮用水异味事件的发生原因,查明污染物质,以利采取有效措施消除或控制危害因素,确保生活饮用水卫生安全,保障消费者身体健康. [方法]对某自来水厂进行现场调查和水源水、出厂水、末梢水水质进行卫生监测与评价. [结果]水源水水质的挥发酚类不符合国家《地面水环境质量标准》(GB 3838-2002)规定的Ⅲ类水质标准;出厂水和末梢水水样中的挥发酚类检测值为<0.002~0.132 mg/L,存在臭和味、挥发酚类等指标不符合国家《生活饮用水卫生标准》(GB 5749-2006)规定要求. [结论]水源水苯酚污染是造成此次饮用水异味事件的主要原因.

关 键 词:饮用水  异味  苯酚  污染  调查

An Investigation on Odor in Drinking Water by Source Water Pollution with Phenol
JIANG Zhao- feng,JIANG Fang-ping,DING Zhen,WEI Zhen-ping,Hao Shi-xuan,XU Hong. An Investigation on Odor in Drinking Water by Source Water Pollution with Phenol[J]. Journal of Environmental & Occupational Medicine, 2012, 29(11): 707-709
Authors:JIANG Zhao- feng  JIANG Fang-ping  DING Zhen  WEI Zhen-ping  Hao Shi-xuan  XU Hong
Affiliation:1.Zhenjiang Center for Disease Prevention and Control, Zhenjiang, Jiangsu 212001, China; 2.Jiangsu Provincial Center for Disease Prevention and Control, Nanjing, Jiangsu 210009, China) The authors declare they have no actual or potential competing financial interests.
Abstract:[ Objective ] To investigate and analyze the cause of an incident of drinking water odor in a city, to identify the pollutants, and to ensure drinking water safety and customer health by identifying and removing the pollutant. [ Methods ] A field investigation was conducted in a water plant after the drinking water odor incident reported. The samples of source water, finished water and peripheral water were monitored and evaluated. [ Results ] The volatile phenol index of source water did not meet the class III water quality standard prescribed in Environmental Quality Standards for Surface Water (GB 3838--2002). The concentrations of volatile phenols tested in finished water and peripheral water samples varied between 0.002 mg/L and 0.132 mg/L, and other indicators such as smell and taste did not conform to the requirements of Standards for DrinMng Water Quality (GB 5749-2006). [ Conclusion ] Phenol pollution of source water is the main cause of the investigated odor incident in drinkin~ water.