2. 复旦大学公共卫生学院,上海,200032
摘    要:[目的]对上海市某区8家餐厅的环境烟草烟雾浓度在《上海市公共场所控制吸烟条例》(简称《控烟条例》)实施前后进行比较,旨在评价《控烟条例》在餐厅的实施效果,为该条例今后的进一步修订提供参考. [方法]采用目的抽样方法,在2008年4月《控烟条例》实施前和2010年12月《控烟条例》实施后选取8家餐厅分别进行基线调查和随访监测,采用AM510个体气溶胶监测仪检测空气中细颗粒物(PM2.5)浓度以代表环境烟草烟雾污染状况. [结果]《控烟条例》实施前后餐厅室内PM2.5浓度分别为147.76、125.15μg/m3,室内PM2.5浓度峰值分别为363.20、272.00μg/m3.《控烟条例》实施前后餐厅室内外PM2.5浓度差值分别为80.44、70.53μg/m3,差异无统计学意义(P>0.05). [结论]《控烟条例》实施前后,餐厅室内PM2.5浓度没有明显变化.部分餐厅大厅内尚无有效控烟措施,环境烟草烟雾暴露问题比较严重,必须采取严格有效禁烟措施减少环境中因吸烟所致的烟雾污染.

关 键 词:餐厅  环境烟草烟雾  空气细颗粒物  控制吸烟

Environmental Tobacco Smoke Density in Some Restaurants of Shanghai
ZHANG Zhi-xing,ZHENG Pin-pin,SHEN Juan,ZHOU Xi-lan,FU Hua. Environmental Tobacco Smoke Density in Some Restaurants of Shanghai[J]. Journal of Environmental & Occupational Medicine, 2012, 29(11): 674-676
Authors:ZHANG Zhi-xing  ZHENG Pin-pin  SHEN Juan  ZHOU Xi-lan  FU Hua
Affiliation:(Institute of Health Inspection, Changning Health Bureau, Shanghai 200051, China; School of Public Health, Fudan University, Shanghai 200032, China). Address correspondence to ZHENG Pin-pin, E-mail: zpinpin@shmu.edu.cn The authors declare they have no actual or potential competing financial interests.
Abstract:[ObjeCive ] To compare environmental tobacco smoke density in 8 restaurants in a district of Shanghai before and after the implementation of Shanghai Regulation on Public Places Smoking Control for effectiveness assessment, and to provide reference for further amendment to this regulation. [ Methods ] AM510 personal aerosol monitor was used to measure PM2.5 concentrations in 8 restaurants in April 2008 (pre-ban) and December 2010 (post-ban) through purposive sampling. [ Results ] The average indoor PM25 concentrations of the 8 restaurants were 147.76 μg/m3 before implementation and 125.15 μg/m3 after the implementation. The peak indoor concentrations were 363.20 μg/m3(pre-ban) and 272.00μg/m3 (post-ban). The difference values between indoor and outdoor PM2.5 concentrations were 80.44 μg/m3 (pre-ban) and 70.53 μg/m3 (post-ban). However, no significant differences were found (P〉 0.05). [ Conclusion ] The findings of the current study indicate no obvious changes in PM2.5 concentrations of indoor space of the selected restaurants since the implementation of Smoking Control Regulation. Currently, there are no effective smoke-free measures in restaurants of Shanghai. Exposure to environmental tobacco smoke is still a serious concern demanding strict and effective actions for tobacco smoke pollution control.
Keywords:restaurants  environmental tobacco smoke  fine particulate matter  tobacco control
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号