Patch technique for repair of a dural tear in microendoscopic spinal surgery
Authors:Shibayama M  Mizutani J  Takahashi I  Nagao S  Ohta H  Otsuka T
Affiliation:Department of Orthopaedic Surgery, Toyokawa City Hospital, Koumei 1-19, Toyokawa City, Aichi 442-8561, Japan. moto@toyokawa-ch-aichi.jp
Abstract:A dural tear is a common but troublesome complication of endoscopic spinal surgery. The limitations of space make repair difficult, and it is often necessary to proceed to an open operation to suture the dura in order to prevent leakage of cerebrospinal fluid. We describe a new patch technique in which a small piece of polyglactin 910 is fixed to the injured dura with fibrin glue. Three pieces are generally required to obtain a watertight closure after lavage with saline. We have applied this technique in seven cases. All recovered well with no adverse effects. MRI showed no sign of leakage of cerebrospinal fluid.
Keywords:
本文献已被 PubMed 等数据库收录!