首页 | 本学科首页   官方微博 | 高级检索  
     

不同大小肾通道对猪肾动脉损伤的实验研究
引用本文:杨后猛,曾国华,邵法明,缪起龙,虞建达,方宁军,李逊,伍筱梅. 不同大小肾通道对猪肾动脉损伤的实验研究[J]. 中华泌尿外科杂志, 2011, 32(5). DOI: 10.3760/cma.j.issn.1000-6702.2011.05.008
作者姓名:杨后猛  曾国华  邵法明  缪起龙  虞建达  方宁军  李逊  伍筱梅
作者单位:1. 宁波大学医学院附属医院泌尿外科,315020
2. 广州医学院第一附属医院微创外科中心泌尿外科
摘    要:目的 探讨不同大小肾通道对离体猪肾动脉的损伤情况.方法 应用经皮肾技术在离体猪肾上分别建立12、14、16……32 F 11组通道,每组40个通道.利用数字减影血管造影技术对离体猪肾动脉造影并分析各组通道对肾动脉的损伤情况.结果 在12~32 F范围内,肾动脉的损伤程度随肾通道直径的增加而递增.20 F和32 F通道相比,有肾动脉损伤的通道数分别为18个和30个,差异有统计学意义(P<0.05).18、20、22 F各组通道对肾动脉损伤之间差异无统计学意义(P>0.05).结论 随肾通道直径的增大,肾动脉损伤的程度逐渐增加.20 F较32 F肾通道能够明显减少肾动脉的损伤.
Abstract:
Objective To investigate the arterial injury in vitro porcine kidney to different size of nephrostomy tracts. Methods The technique of percutaneous nephrostomy was applied to establish 11 groups of different size of nephrostomy tracts from 12 F to 32 F,with 40 tracts in every group.The technique of digital subtraction angiography (DSA) was used to inspect and analyze arterial injury. Results In the range from 12 F to 32 F,the damage of arterial injury increased with the size of the tract diameter.In groups of 20 F and 32 F,the number of nephrostomy tracts with serious arterial injury was 18 (18/40) and 30 (30/40) respectively,and the difference was statistically significant (P<0.05).There was no statistical difference between groups 18 F、20 F、and 22 F. Conclusions The damage of renal arterial injury increased with the size of the nephrostomy tract.Atract of 20 F reduees arterial injury compared with a tract of 32 F.

关 键 词:经皮肾穿刺取石术  出血  动脉造影术  动物实验

An experimental study measuring arterial injury in vitro porcine kidney in different sizes of nephrostomy tracts
YANG Hou-meng,ZENG Guo-hua,SHAO Fa-ming,MIU Qi-long,YU Jian-da,FANG Ning-jun,LI Xun,WU Xiao-mei. An experimental study measuring arterial injury in vitro porcine kidney in different sizes of nephrostomy tracts[J]. Chinese Journal of Urology, 2011, 32(5). DOI: 10.3760/cma.j.issn.1000-6702.2011.05.008
Authors:YANG Hou-meng  ZENG Guo-hua  SHAO Fa-ming  MIU Qi-long  YU Jian-da  FANG Ning-jun  LI Xun  WU Xiao-mei
Abstract:Objective To investigate the arterial injury in vitro porcine kidney to different size of nephrostomy tracts. Methods The technique of percutaneous nephrostomy was applied to establish 11 groups of different size of nephrostomy tracts from 12 F to 32 F,with 40 tracts in every group.The technique of digital subtraction angiography (DSA) was used to inspect and analyze arterial injury. Results In the range from 12 F to 32 F,the damage of arterial injury increased with the size of the tract diameter.In groups of 20 F and 32 F,the number of nephrostomy tracts with serious arterial injury was 18 (18/40) and 30 (30/40) respectively,and the difference was statistically significant (P<0.05).There was no statistical difference between groups 18 F、20 F、and 22 F. Conclusions The damage of renal arterial injury increased with the size of the nephrostomy tract.Atract of 20 F reduees arterial injury compared with a tract of 32 F.
Keywords:Percutaneous nephrolithotomy  Hemorrhage  Arteriography  Animal studies
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏