首页 | 本学科首页   官方微博 | 高级检索  
检索        


Clinical dosimetry during cerebral arteriography
Authors:M Chopp  H D Portnoy  R Schurig  P Croissant
Institution:(1) Department of Physics, Oakland University, USA;(2) Department of Health Sciences, Oakland University, USA;(3) Department of Surgery (Neurosurgery), Crittenton Hospital Rochester, Michigan, USA
Abstract:Summary Radiation dosimetry measurements on angiographer, X-ray technician and patient were performed during 18 femerocerebral angiograms. Lithium fluoride (LiF) thermoluminescent dosimeters were placed on various body areas to measure X-ray exposure. The results of this study indicate that radiation exposure received by medical personnel are well within the maximum permissible dose range established by the National Council of Radiation Protection. However, radiation exposure levels to radiosensitive areas of the patient are significant. A method to reduce patient exposure during femerocerebral arteriograms is suggested.
Keywords:Femerocerebral angiography  Dosimetry  Radiation safety
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏