首页 | 本学科首页   官方微博 | 高级检索  
     

术中超声监测脑脊液流动在Chiari I畸形矫正术中的应用
引用本文:江凌,张华斌,刘彬,崔立刚,王金锐,贾建文. 术中超声监测脑脊液流动在Chiari I畸形矫正术中的应用[J]. 中华医学超声杂志(电子版), 2009, 6(6): 45-47
作者姓名:江凌  张华斌  刘彬  崔立刚  王金锐  贾建文
作者单位:1. 北京大学第三医院超声诊断科,100191
2. 北京大学第三医院神经外科,100191
摘    要:目的评价术巾多普勒超声监测脑脊液流动在Chiari电图I畸形矫正术中的应用。方法对20例Chiari I型患者行术巾超声检查,在手术过程中实时监测脑脊液流动及其流动速度。结果20例患者彩色多普勒超声均可实时监测到脑脊液的流动。颅骨减压术后,19例患者脑脊液呈低速流动或消失,进一步行硬膜成形术后脑脊液呈双方向流动,即收缩期由头侧向足侧流动,舒张期反之;最大流速为4~13cm/s,并可见随呼吸节律的变化。1例患者在颅骨减压术后即出现上述典型脑脊液流动频谱,超声提示减压充分,未再进行硬膜成形术;余患者在超声显示脑脊液双向流动后结束手术,除1例症状无明显改善外,其他患者症状明显减轻。结论术中彩色多普勒超声可实时监测Chiari I畸形患者腩脊液流动,并可提示脑脊液循环流动的恢复,客观评价手术效果。

关 键 词:超声检查  手术中监测  脑脊液  阿诺德基阿里畸形

Monitoring of cerebrospinal fluid flow by intraoperative ultrasound in patients with Chiari I malformation
JIANG Ling,ZHANG Hua-bin,LIU Bin,CUI Li-gang,WANG Jin-rui,JIA Jian-wen. Monitoring of cerebrospinal fluid flow by intraoperative ultrasound in patients with Chiari I malformation[J]. Chinese Journal of Medical Ultrasound, 2009, 6(6): 45-47
Authors:JIANG Ling  ZHANG Hua-bin  LIU Bin  CUI Li-gang  WANG Jin-rui  JIA Jian-wen
Affiliation:. (Department of Diagnostic Ultrasound, Peking University Third Hospital, Beijing 100191, China)
Abstract:Objective To investigate the feasibility of intraoperative ultrasound (IOUS) for imaging the flow of cerebrospinal fluid (CSF) in Chiari type-I malformation. Methods Twenty Chiari I type patients were scanned by IOUS with color Doppler flow imaging(CDFI) . The CSF flow and the velocity were monitored at different time during steps of operation. Results The flow of CSF was dectected in all 20 cases by real-time IOUS-CDFI. The CSF flow was very slow or indistinct just 'after bony decompression ( cranieetomy + laminecto- my) in 19 patients, but bi-dlrectional, caudal-directed in systolic phase and cranial-directed in diastolic phase were more vigorous with a peak flow rate of 4-13 cm/s after duralplasty. The waveform exhibited respiratory variations. Only 1 patient showed typical CSF flow as mentioned after craniectomy which meant enough decompression without further duralplasty. All operations were ended after IOUS-CDFI demonstrating bi-directional flow of CSF. The patients were relieved clearly excluding one patient without significant improvement in symptoms. Conclusions IOUS-CDFI can monitor the CSF flow during posterior fossa decompression which provide information about re-circulation flow of CSF and competently evaluate the effectiveness of the surgery.
Keywords:Ultrasonography  Intraoperative monitoring  Cerebrospinal fluid  Arnold-Chiari malfor- mation
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《中华医学超声杂志(电子版)》浏览原始摘要信息
点击此处可从《中华医学超声杂志(电子版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号