首页 | 本学科首页   官方微博 | 高级检索  
检索        

基于眼电的智能输入系统研究
引用本文:郜东瑞,甘玉龙,李鹏霄,谢佳欣,尧德中,刘铁军.基于眼电的智能输入系统研究[J].中国生物医学工程学报,2015,34(6):662-669.
作者姓名:郜东瑞  甘玉龙  李鹏霄  谢佳欣  尧德中  刘铁军
作者单位:电子科技大学生命科学与技术学院,成都 610054
基金项目:国家重大科学仪器开发专项(2012YQ120046);国家高技术研究发展计划(863计划)(2015AA020510)
摘    要:为了帮助肢体运动功能障碍患者与外界交流,设计一套基于眨眼眼电的便携式智能输入系统,使用者仅通过眨眼便能控制人机交互界面上的虚拟键盘进行字符输入。该系统中的信号采集模块先对眼电信号经行预处理,然后将其转换为数字信号传输至微处理。微处理首先通过数字形态学方法滤除信号中的尖峰噪声,然后通过动态阈值和归一化、微分算法识别主动眨眼信号,并完成对虚拟键盘的控制,实现中文、英文或数字的输入。选择12名受试者分别在常规实验室、电磁干扰较大的磁共振设备室和户外的运动场进行测试。结果表明,该系统在上述3个不同的环境中能够准确识别眨眼信号并实现中文、英文及数字的输入,而且输入字符的平均准确率不低于98%,中文、英文字符和数字的平均输入速度分别为(2.8±0.3)、(6.6±0.35)、(9.7±0.38)个/min。因此,该系统的抗干扰能力较强,能够帮助肢体运动功能障碍患者实现与外界交流。

关 键 词:眼电图  人机交互  嵌入式系统  图形化用户界面  

Research of Intelligent Speller System Based on EOG
Gao Dongrui GanYulong Li Pengxiao Xie Jiaxin Yao Dezhong Liu Tiejun#.Research of Intelligent Speller System Based on EOG[J].Chinese Journal of Biomedical Engineering,2015,34(6):662-669.
Authors:Gao Dongrui GanYulong Li Pengxiao Xie Jiaxin Yao Dezhong Liu Tiejun#
Institution:School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu 610054, China
Abstract:A portable intelligent speller system based on blink electro oculogram (EOG) was designed to help patients of limb movement function disorders to communicate with other people. The user can control virtual keyboard to spell characters by blinking on human-computer interaction (HCI) interface. The signal would be pre-processed by acquisition module of the system. Then the signal was converted to digital signal, and the digital signal was transmitted to microprocessor. Pike noise of the digital signal was firstly filtered by mathematical morphology. Then dynamical threshold algorithm and normalization, differential algorithm were used to detect the blink. According to the information of EOG, virtual keyboard was controlled to spell characters by microprocessor. In this paper, 12 subjects were tested the system in three occasions (routine laboratory, magnetic resonance imaging equipment room with the large electromagnetic interference, and outdoor playground). Results showed that the system could accurately identify blink signal and spell characters including Chinese, English and numbers. Besides, the mean average precision of input character was above 98%. The average input speeds of Chinese character, English character and number were 2.8±0.3, 6.6±0.35 and 9.7±0.38 (per/min), respectively. Hence the system which has higher interference rejection is appropriate for patient of limb movement function disorders.
Keywords:electro-oculogram(EOG)  human-computer interaction  embedded system  graphical user interface  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国生物医学工程学报》浏览原始摘要信息
点击此处可从《中国生物医学工程学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号