首页 | 本学科首页   官方微博 | 高级检索  
     


Custom extracellular matrix cylinder mitral valve in a pediatric patient
Authors:Clifford L. Cua MD  Pace Johnston MD  Jill Harmon RDCS  Kathryn Shelton RDCS  Patrick I. McConnell MD
Affiliation:Heart Center, Nationwide Children's Hospital, Columbus, OH, USA
Abstract:Mitral valve construction using extracellular matrix (ECM) is a relatively new procedure. In this case, a 15‐month‐old boy with a history of severe mitral valve regurgitation secondary to endocarditis underwent mitral valve surgery. Mitral valve repair was not possible, and thus, a 17 mm extracellular matrix cylinder valve (ECM‐CV) was constructed for valve replacement. The ECM‐CV is clearly imaged using echocardiography, especially three‐dimensional imaging, that helped define valve function. As the use of ECM for valve construction increases, echocardiography will play an essential role in evaluating the function and mechanics of these novel valves.
Keywords:bioprosthetic valve  echocardiography  extracellular matrix graft  mitral valve  three‐dimensional echocardiography