MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy |
| |
Authors: | Lars Schimmöller Michael Quentin Christian Arsov Andreas Hiester Christian Buchbender Robert Rabenalt Peter Albers Gerald Antoch Dirk Blondin |
| |
Affiliation: | 1. Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Moorenstr. 5, 40225, Dusseldorf, Germany 2. Department of Urology, University Dusseldorf, Medical Faculty, Moorenstr. 5, 40225, Dusseldorf, Germany
|
| |
Abstract: | Purpose This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. Methods In 235 consecutive patients [aged 65.7?±?7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. Results In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern?≥?4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. Conclusion The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. Key Points ? T2WI + DWI + DCE achieved the highest accuracy in patients with higher grade PCa ? T2WI + DWI + DCE was more accurate for peripheral- than for transitional-zone PCa ? DCE increased PCa detection accuracy in the peripheral zone ? DWI was the leading sequence in the transitional zone |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|