首页 | 本学科首页   官方微博 | 高级检索  
检索        


In vivo influence of residual moisture on microtensile bond strengths of one-bottle adhesives
Authors:Perdigão Jorge  Geraldeli Saulo  Carmo André R P  Dutra Hélio R
Institution:Associate Professor and Director, Division of Operative Dentistry, Department of Restorative Sciences, University of Minnesota, Minneapolis, Minnesota;Lasby Visiting Professor, Department of Oral Sciences;Clinical Assistant Professor, Division of Operative Dentistry, University of Minnesota, Minneapolis, Minnesota;Assistant Professor, Department of Operative Dentistry, University of Mogi das Cruzes, Mogi das Cruzes, SP, Brazil;Private Practice, São Paulo, SP, Brazil
Abstract:Purpose: This study evaluated the microtensile bond strengths of three dentin adhesives applied on clinically moist dentin or on dentin that was dried with air for 5 seconds. The null hypothesis to test was that the level of residual moisture does not influence bond strengths when restorations are placed in vivo.
Materials and Methods: Twenty-four premolars scheduled to be extracted for orthodontic reasons from patients between the ages of 15 and 23 years were restored with one of the following adhesive systems followed by a mini hybrid composite resin: Excite (Ivoclar/Vivadent), an ethanol-based dentin adhesive; Prime & Bond NT (Dentsply/Caulk), an acetone-based dentin adhesive; and Single Bond (3M ESPE), an ethanol and water-based dentin adhesive. After extraction, the specimens were sectioned with a slow-speed diamond saw in two perpendicular directions to obtain sticks with a cross-section of 0.7 ± 0.2 mm2. The specimens were attached to a Geraldeli device and fractured using a universal testing machine at a crosshead speed of 1 mm per minute.
Results: For each dentin adhesive, there were no statistical differences between means for dry dentin versus moist dentin. Single Bond and Prime & Bond NT ranked in the same statistical subset regardless of the moisture condition of the substrate. Both Excite, dry, and Excite, moist, resulted in statistically lower bond strengths than Single Bond, moist, but similar to those of Single Bond, dry, Prime & Bond NT, moist, and Prime & Bond NT, dry.
CLINICAL SIGNIFICANCE
In this study, the level of residual moisture did not influence microtensile bond strengths. Clinically, the degree of moisture left on the dentin surface upon rinsing off the etching gel may not be as relevant as previously reported in laboratory studies.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号